Led Signals; Technical Specifications - Nice BiDi-Dimmer Instructions And Warnings For Installation And Use

Bidirectional interface for lights indoor
Table of Contents

Advertisement

6

LED SIGNALS

6.1 - Programming menu
When pressing and holding the programming pushbutton on the control unit, the LED will signal consecutive positions of the programming menu.
Table A17 - menu positions when holding the programming pushbutton
Color
1
Red
2
Orange
3
Blue
4
Green
5
Violet
6
White
7
Yellow
6.2 - Other signals
Table A18 - other LED signals
Color
2 red flashes
3 red flashes
3 orange flashes
6 red flashes
6 orange flashes
3 yellow flashes
5 yellow flashes
7

TECHNICAL SPECIFICATIONS

The product BiDi-Dimmer is produced by Nice S.p.a. (TV). Warnings: - All technical specifications stated in this section refer to an ambient
temperature of 20 °C (± 5 °C) - Nice S.p.a. reserves the right to apply modifications to the product at any time when deemed necessary, while
maintaining the same functionalities and intended use.
BiDi-Dimmer
Type
Power supply
Rated current
Rated power
Rated power
with connected Nice LED Adaptor
Recommeded wires cross-section
Required circuit breaker
Casing protection rating
Operating temperature
Dimensions (mm)
Weight
Description
Memorization in Mode I
Memorization in Mode II
Calibration
Auto OFF settings
Switch type settings
Favourite brightness level settings
Reset
Description
No transmitters memorized
Transmitter memorized in Mode I
Transmitter memorized in Mode II
Memory for transmitters full (Mode I)
Memory for transmitters full (Mode II)
Transmitter deleted from memory
Control unit restored to factory settings
in-wall/flush box mounted control unit for single light source
Resistive-capacitive loads (fluorescent tube lamp, electronic transformer, LED):
Resistive-capacitive loads (fluorescent tube lamp, electronic transformer, LED):
Compliant with IEC/EN 60898-1; Curve code: B; Rated current: up to 16 A;
100–240 V AC, 50/60 Hz
1.1 A
Resistive loads (incandescent and halogen):
50–250 W for Vn =240 V; 25–125 W for Vn = 120 V
50–200 VA for Vn =240 V; 25–100 VA for Vn = 120 V
Resistive-inductive loads (ferromagnetic transformers):
50–220 VA for Vn =240 V; 25–110 VA for Vn = 120 V
5–200 VA for Vn =240 V; 5–100 VA for Vn = 120 V
0.5–4 mm
for 1 wire; 0.5–1.5 mm
2
Breaking capacity: 6 kA; Rated insulation voltage: 500 V;
Rated impulse withstand voltage: 4 kV;
IP 20
0–35 °C
45 x 36 x h 23
34 g
for 2 wires
2

Advertisement