Hilti SR 6-22 Original Operating Instructions page 30

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
6.3
Removing the saw blade
CAUTION
Risk of injury! The accessory tool may be hot and/or have sharp edges.
▶ Wear protective gloves when changing the accessory tool.
▶ Never lay down a hot accessory tool on a flammable surface.
1. Push the locking lever up as far as it will go and hold it in this position.
2. Pull the blade forward out of the blade holder.
3. Allow the locking lever to return to its original position.
7
Care and maintenance
WARNING
Risk of injury with battery inserted !
▶ Always remove the battery before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt.
Carefully clean the air vents, if present, with a dry, soft brush.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Clean and lubricate the blade holder from the outside at regular intervals. Use the Hilti spray #314648
for this purpose.
Use a dry, clean cloth to clean the contacts of the product.
Care of the lithium­ion batteries
Never use a battery with clogged air vents. Clean the air vents carefully using a dry, soft brush.
Avoid unnecessary exposure of the battery to dust and dirt. Never expose the battery to high levels of
moisture (e.g. by being dipped in water or left in the rain).
If a battery has been soaked by moisture, treat it as a damaged battery. Isolate it in a non-flammable
container and consult Hilti Service.
Keep the battery free of extraneous oil and grease. Do not permit dust or dirt to accumulate unnecessarily
on the battery. Clean the battery with a dry, soft brush or a clean, dry cloth. Do not use cleaning agents
containing silicone as these can attack the plastic parts.
Do not touch the contacts of the battery and do not remove the factory-applied grease from the contacts.
Use only a slightly damp cloth to clean the housing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.
Maintenance
Check all visible parts and controls for signs of damage at regular intervals and make sure that they all
function correctly.
Do not use the product if signs of damage are found or if parts malfunction. Immediately have the product
repaired by Hilti Service.
After cleaning and maintenance, install all guards and protective devices and check that they are in full
working order.
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables. Spare
parts, consumables and accessories approved by Hilti for use with your product can be found at your
Hilti Store or online at: www.hilti.group
7.1
Replacing the contact shoe
1. Remove the saw blade. → page 24
2. Press the contact shoe lock button.
3. Pull the contact shoe out.
4. Press the contact shoe lock button.
24
English
8
9
2243124
*2243124*

Advertisement

Table of Contents
loading

Table of Contents