Code
Description
E03
DC-bus
overvoltage error
E04
Rotor blocked
E05
EEPROM Data
memory error
E06
Grid voltage error
E07
Motor winding
temperature error
E08
Power module
temperature error
E09
Generic hardware
error
E11
LOW error
E12
Pressure sensor
error
E14
Low pressure error
E15
Loss of phase error
E30
Multi-pump
protocol error
E44
External analogue
reference error
See also Par. 6.3.2 and Par. 6.4.3.
Cause
• DC-bus overvoltage
• External conditions cause the
operation of the pump from
generator
• Motor stall
• Loss of rotor synchronism or
rotor blocked by external
materials
EEPROM Data memory
corrupted
Voltage supply out of operating
range
Motor thermal protection trip
Frequency converter thermal
protection trip
Hardware error
Lack of water detection (if P48=
ERR)
Missing pressure sensor (not
present in ACT mode)
Pressure below minimum
threshold (not present in ACT
mode)
One of the three power supply
phases is missing (three-phase
versions only)
Incompatible multi-pump
protocol
External analogue signal missing
or out of range (if P40 = ISP)
en – Original instructions
Solution
Check:
• the system configuration
• the position and integrity of the non-return
valves
• Check that there are no foreign bodies
preventing the pump from turning
• Stop the pump for 5 minutes and then start it
again
If the problem continues, contact Xylem or the
Authorised Distributor
Stop the pump for 5 minutes and then restart it
again; if the problem continues, contact Xylem or
the Authorised Distributor
Check:
• the voltage
• the connection of the electric system
• Check for impurities near the impeller and rotor.
Remove them if necessary
• Check the conditions of installation, and the
water and air temperature
• Wait for the motor to cool down
• If the error persists, stop the pump for 5
minutes and then start it again
If the problem continues, contact Xylem or the
Authorised Distributor
Check the conditions of installation, and the air
temperature
Stop the pump for 5 minutes and then restart it
again; if the problem continues, contact Xylem or
the Authorised Distributor
Check the water level inside the tank
Check the condition of the sensor connection
cables
Check the settings of parameters P45 and P46
Check the connection to the power supply network
Bring all the units to the same firmware version
Check:
• the P40 parameter setting
• External analog signal source and cables
(terminals 9-10 for the single-phase version,
terminals 17-18 for the three-phase version)
47