Xylem LOWARA e-SVE Additional Installation, Operation And Maintenance Instructions page 18

Smart pump range
Table of Contents

Advertisement

en – Original instructions
Position
number
1
2
3
4
5
6
7
8
9
10
11
Pre-assembled ex factory components
Component
Plug for Cable Gland
Cable gland and lock nut
Cable Gland
Optional components
Component
Sensors
RS485 Module
Adaptor
18
Description
Screw
Terminal Box Cover
Optional module with strip
M12 I/O cable gland
M20 cable gland for power supply cables
M16 I/O cable gland
Drive (single-phase model)
Motor
Screw
Drive (three-phase model)
Spacer
Quantity
M12
3
M16
1
M20
1
M12
3
M16
1
M20
1
Description
The following sensors can be used with the unit:
• Level-sensor
For the connection of a multi-pump system to a supervision system, via cable (Modbus or BACnet
MS/TP protocol)
M20 Metric to 1/2" NPT Adapter (item is always supplied for US market)
Notes
3.7 to 7.0 mm (0.145÷0.275 in)
Cable Outer Diameter:
4.5 to 10.0 mm (0.177÷0.394 in)
7.0 to 13.0 mm (0.275÷0.512 in)
Tightening torque ±15%
[Nm]
[in•lbs]
1.4
12.4
-
-
-
-
2.0
17.7
2.7
23.9
2.8
24.8
-
-
-
-
6.0
53.1
-
-
-
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lowara vmeLowara e-hmeLowara e-svie

Table of Contents