Xylem LOWARA e-SVE Additional Installation, Operation And Maintenance Instructions page 27

Smart pump range
Table of Contents

Advertisement

Item
Terminals Ref. Description
Fault signal
Auxiliary Voltage
Supply
P2IN/S+
Analog input
0-10V
P2C/S-
External Pressure
sensor [also
Differential]
START
External Start/Stop
1~
STOP
External Lack of
LOW+
Water
LOW-
Communication
Bus
GND
Communication
Bus
GND
Fault signal
Motor running
signal
Auxiliary Voltage
Supply
Analog input
0-10V
External Pressure
3~
sensor [also
Differential]
External pressure
sensor
Start
External Start/Stop
Stop
LoW+
External Lack of
Water
LoW-
Communication
Bus
C
4 COM - error status relay
NO
5 NO - error status relay
15V
6 Auxiliary voltage supply +15 VDC
7 Actuator mode 0-10 V input
8 GND for 0-10 V input
Power supply external sensor +15
P1+
9
VDC
P1-
10 External sensor 4-20 mA input
11 External ON/OFF input reference
12 External ON/OFF input
13 Lack water input
14 Low water reference
B1
15 RS485 port 1: RS485-1N B (-)
A1
16 RS485 port 1: RS485-1P A (+)
17 Electronic GND
RS485 port 2: RS485-2N B (-) active
B2
18
only with optional module
RS485 port 2: RS485-2P A (+) active
A2
19
only with optional module
20 Electronic GND
C
25 COM - error status relay
NO
24 NO - error status relay
C
23 Common contact
NO
22 Normally open contact
15V
21 Auxiliary voltage supply +15 VDC
S+
20 Actuator mode 0-10 V input
S-
19 GND for 0-10 V input
Power supply external sensor +15
P1+
18
VDC
P1-
17 External sensor 4-20 mA input
Power supply external sensor +15
P2+
16
VDC
P2-
15 Sensor 4-20 mA input
14 External ON/OFF input
13 External ON/OFF input reference
12 Lack water input
11 Low water reference
RS485 port 2: RS485-2N B (-) active
B2
10
only with optional module
en – Original instructions
Notes
Closed: error
Open: no error or unit off
15VDC, Ʃ max. 100 mA
0÷10 VDC
GND, electronic ground (for S+)
15VDC, Ʃ max. 100 mA
4÷20 mA
Default short circuited. Pump is enabled
to RUN
Default short circuited.
Lack of water detection: enabled
ACT, HCS control mode: RS 485 port1 for
external communication
MSE, MSY control mode: RS 485 port 1
for multi-pump systems
RS 485 port2 for external
communication
Closed: error
Open: no error or unit off
In case of power cables: use the M20
cable gland
Closed: motor in operation
Open: motor not in operation
In case of power cables: use the M20
cable gland
15VDC, Ʃ max. 100 mA
0÷10 VDC
GND, electronic ground (for S+)
15VDC, Ʃ max. 100 mA
4÷20 mA
15VDC, Ʃ max. 100 mA
4÷20 mA
Default short circuited. Pump is enabled
to RUN
Default short circuited. Lack of water
detection: enabled
RS 485 port2 for external
communication
27

Advertisement

Table of Contents
loading