Martindale Electric ET5 Instruction Manual page 24

Electrical tester
Table of Contents

Advertisement

AC Voltage
Range
Resolution
500mV
0.1mV
5V
0.001V
50V
0.01V
500V
0.1V
600V
1V
Overload Protection: 600V DC or AC rms
A
DC Current (
Range
Resolution
200A
0.1A
Maximum input current: 200A
µA
DC Current (
Range
Resolution
500µA
0.1µA
Maximum input current: 500µA
AC Current
Range
Resolution
200A
0.1A
Maximum input current: 200A
Resistance
Range
Resolution
500Ω
0.1Ω
5kΩ
0.001kΩ
50kΩ
0.01kΩ
500kΩ
0.1kΩ
5MΩ
0.001MΩ
50MΩ
0.01MΩ
Overload Protection: 600V DC or AC rms
Input
Impedance
1 MΩ
)
function
Accuracy
± (2.0% of rdg + 5 dgts)
function)
Voltage burden
1V
Accuracy (50 Hz to 60 Hz)
± (2.0% of rdg + 10 dgts)
Open circuit voltage Accuracy
-3.2V DC
-1.1V DC approx
Accuracy
Not specified
50-60Hz ± (1.2% of rdg + 5 dgts)
60-500Hz ± (2.0% of rdg + 5 dgts)
Accuracy
± (1.0% of rdg + 2 dgts)
± (1.0% of rdg + 5 dgts)
± (1.5% of rdg + 5 dgts)
± (3.0% of rdg + 5 dgts)