Martindale Electric VT4 Instruction Manual

Martindale Electric VT4 Instruction Manual

Voltage tester

Advertisement

Quick Links

VT4
VOLTAGE
TESTER
Instruction
Manual
ALWAYS READ THESE INSTRUCTIONS
BEFORE PROCEEDING
Thank you for buying one of our products. For
safety and full understanding of its benefi ts
please read this manual before use. Technical
support is available from 01923 441717 and
support@martindale-electric.co.uk.
CONTENTS
1
2
3
Range Button
4
5
Specifi cations
1
1
2
4
4
4
4
4
5
5
5
6
6
6
7
7
9
9
9
10
10
11

Advertisement

Table of Contents
loading

Summary of Contents for Martindale Electric VT4

  • Page 1: Table Of Contents

    1.2 Precautions Introduction 2.1 Inspection 2.2 Description 2.3 Accessories 2.4 Battery Installation Operation 3.1 VT4 Layout 3.2 ON/OFF and Voltage Sensitivity Range Button 3.3 Low Battery Indication 3.4 Torch 3.5 Proving Check 3.6 Testing Considerations 3.7 Testing for the Presence of Voltage Maintenance 4.1 Battery Replacement...
  • Page 2: Safety Information

    1 SAFETY INFORMATION 1.2 Precautions This product has been designed with your safety REMEMBER: in mind, but please pay attention to the following SAFETY IS NO ACCIDENT warnings and cautions before use. These instructions contain both information and warnings that are necessary for the safe Warnings operation and maintenance of this product.
  • Page 3: Introduction

    Do not use the voltage tester during rain or distributor immediately. precipitation. 2.2 Description The voltage tester will not detect DC voltage. The Martindale VT4 is a non-contact voltage tester with the following features: Cautions Contactless voltage testing between 12V and Avoid severe mechanical shock or vibration and 1000V extreme temperature.
  • Page 4: Operation

    Pressing the ON/OFF button (5) for 1 second the voltage source, the red LED must illuminate will turn on the VT4. The red LED in the LED and the buzzer must sound as in table 1, for the illumination area (3) will fl ash at a rate of once a selected voltage sensitivity range setting.
  • Page 5: Testing Considerations

    While taking all required safety precautions 3.6 Testing Considerations position the test tip (1) of the VT4 in close From some directions the neutral and earth proximity to the cable, UUT or location to be conductors in cables will shield the live, so tested for voltage.
  • Page 6: Maintenance

    4.3 Repair and Service There are no user serviceable parts in this unit. 4.1 Battery Replacement Return to Martindale Electric if faulty. Our service To gain access to the battery compartment, department will quote promptly to repair any fault press down on the square recess and pull back that occurs outside the guarantee period.
  • Page 7: Warranty

    5. WARRANTY AND LIMITATION OF LIABILITY unenforceable by a court or other decision-maker This Martindale product is warranted to be free of competent jurisdiction, such holding will not from defects in material and workmanship under affect the validity or enforceability of any other normal use and service.
  • Page 8 Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900 Class II, Double insulation E-mail: sales@martindale-electric.co.uk IP rating: IP64 to BSEN 60529 Website: www.martindale-electric.co.uk © 2018 Martindale Electric Company Ltd. Registered in England No. 3387451. E. & O.E. LITVT4 Rev2 Conforms to BS EN61326-1...

Table of Contents