The Digital Control Panel system is an intricate and valuable piece of technology. For protection from power surges and electrical
shorts, consult the wire diagram below to ensure your power source is sufficient for the operation of the unit.
PB – ELECTRIC REQUIREMENTS
110-120 V, 60 Hz, 275 W, 3-PRONG GROUNDED PLUG
NOTE: Electrical components, passed by product safety testing and certification services, comply
with a testing tolerance of ± 5-10 percent.
Disconnect power supply
before maintenance or for
service. Remove Ash Clean-
out Tray. Carefully flip the
unit upside-down on a
clean and level surface,
to prevent any damage to
the Control Panel.
FUEL INPUT RATING:
1.5 KG/H (3.3LB/H)
GROUNDED
POWER CORD
IGNITOR ASSEMBLY /
INDEX
HD CARTRIDGE HEATER
110-120V, 200 W,
K : BLACK
0.375" X 5.000"
W : WHITE
R : RED
Y : YELLOW
P : PURPLE
O : ORANGE
G : GREEN

ELECTRICAL WIRE DIAGRAM

Unscrew and remove the Ash
Clean-out Housing (3 screws)
and the Auger Motor Housing
(6 screws) from the unit.
K
K
W
W
G
GROUND
W
P
W
W
W
AUGER MOTOR
& FEED SYSTEM
110-120 V, 60 Hz,
2 RPM MOTOR
Unscrew and carefully remove
the Auger Box Housing (4 screws)
from the unit. Disconnect spade
connectors upon removing.
GRILL PROBE
W
W
R
O
W
Y
R
W
R R
Y
Y
DRAFT FAN
110-120 V, 60 Hz,
1 PHASE
Access wiring components
located in both housing
compartments.
CONTROL
PANEL
W
W
LIGHT
110 V, 25 W