Placing The Line In Service; Placing The Hlu Under Hmu Management - ADC Soneplex HMS-358 Installation And Verification Manual

Hide thumbs Also See for Soneplex HMS-358:
Table of Contents

Advertisement

Installing Multiplexers
P
L
LACING THE
INE IN
After the line installation is complete, the line must be placed in service by:
enabling the alarms on the HLU
placing the DS1 interface in service at the HXU

Placing the HLU Under HMU Management

Step
Procedure
The following procedure assumes proper TAO login.
For proper login procedure, please refer to
page
1
From the Network Status screen, type the number of the desired shelf (1 through 32) and then press
ENTER
.
2
From the Shelf Status screen, press
3
Type the slot number of the line unit you want to enable.
4
Press an appropriate
5
Proceed to
"Placing the Line Unit in Service at the HXU" on page
? ? ? ?
Installer Signature
If an HLU card is hot-swapped while under HMU management, no setup is required. All
configuration settings are automatically downloaded from the HMU.
If the HMU is managing the line unit, only the HMU maintenance terminal (ASCII terminal or PC
running a terminal emulation program) can configure the line unit.
Removal of the HMU from the chassis enables the front panel craft port on the HLU.
When an HMU is replaced, the new HMU rebuilds its configuration database from the active
line units.
66
S
ERVICE
32.
A
to select Alarm Management.
Y
or
N
response for the alarm setting you are changing.
January 12, 2001
"Using the Terminal Access Option" on
67.
LTPH-SM-1014-03, Issue 3