BLAUBERG Ventilatoren Line User Manual

BLAUBERG Ventilatoren Line User Manual

Axial fan

Advertisement

Quick Links

AXIAL FAN
Line
User's manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Line and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for BLAUBERG Ventilatoren Line

  • Page 1 AXIAL FAN Line User’s manual...
  • Page 2: Table Of Contents

    Manufacturer’s warranty ..........................................14 This user’s manual is a main operating document intended for technical, maintenance, and operating staff. The manual contains information about purpose, technical details, operating principle, design, and installation of the Line unit and all its modifications.
  • Page 3 PLEASE READ THE USER’S MANUAL CAREFULLY PRIOR TO INSTALLING, CONNECTION TO POWER MAINS AND OPERATING THE UNIT. THE MANUFACTURING COMPANY SHALL NOT BE RESPONSIBLE FOR DAMAGE TO HEALTH AND PROPERTY OF THE CUSTOMER CAUSED BY THE CUSTOMER’S VIOLATING THE USER’S MANUAL. FOLLOW THE USER’S MANUAL REQUIREMENTS TO ENSURE DURABLE OPERATION OF THE UNIT, ITS MECHANICAL AND ELECTRICAL RELIABILITY.
  • Page 4 Deformation of the casing may result in motor jam and excessive noise. Misuse of the unit and any unauthorised modifications are not allowed. Do not expose the unit to adverse atmospheric agents (rain, sun, etc.). Transported air must not contain any dust or other solid impurities, sticky substances, or fibrous materials.
  • Page 5 order to incorporate the latest technological developments. Never touch the unit with wet or damp hands. Never touch the unit when barefoot. This unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the unit by a person responsible for their safety.
  • Page 6 Ensure that the unit is switched off from the supply mains before removing the guard. THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE. DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
  • Page 7: Delivery Set

    DELIVERY SET — 1 pc. Screws and dowels — 4 pcs. Plastic screwdriver (only for the models with a timer) — 1 pc. User’s manual — 1 pc. Packing box — 1 pc. BRIEF DESCRIPTION The unit described herein is an axial fan for exhaust ventilation of small and medium-sized utility spaces. The fan is designed for connection to Ø...
  • Page 8: Designation Key

    DESIGNATION KEY Line Variations of the base model: _: ball bearing and backdraft damper KO by default e: slide bearing, without backdraft damper e1: slide bearing with backdraft damper KO e2: ball bearing, without backdraft damper K1: ball bearing with backdraft damper KO1...
  • Page 9: Mounting

    MOUNTING The fan is designed for wall (with the motors on ball and slide bearings) or ceiling mounting and can be used for direct outdoor air exhaust through a round duct or a duct system. In case of installation through a duct system, select the duct cross section in accordance with the fan size (Fig. 1). 1.
  • Page 10 QF : double pole circuit breaker N : neutral LT: timer control line WARNING! The power cable may only be laid through the hole in the casing provided by the manufacturer. Laying the power cable through a manually drilled hole will not be the liability of the manufacturer and will void the warranty.
  • Page 11: Electronic System Operation Algorithm

    ELECTRONIC SYSTEM OPERATION ALGORITHM The T model fans equipped with a timer are activated by control voltage application to input terminal LT by an external switch S (e.g. indoor light switch). After the control voltage is off, the fan continues to operate within the set time period adjustable from 2 to 30 minutes by the timer.
  • Page 12: Technical Maintenance

    WARNING! Do not allow water or liquid come into contact with electric components! TROUBLESHOOTING Problem Possible reason Troubleshooting Make sure the power supply line No power supply. is connected correctly, otherwise When the unit is connected to power troubleshoot the connection error.
  • Page 13: Storage And Transportation Regulations

    STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to + 40 °C and relative humidity up to 70 %. • Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
  • Page 14: Manufacturer's Warranty

    MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/ EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 15 • Replacement and use of any assemblies, parts and components not approved by the manufacturer. • Unit misuse. • Violation of the unit installation regulations by the user. • Violation of the unit control regulations by the user. • Unit connection to power mains with a voltage different from the one stated in the user's manual. •...
  • Page 16 D [mm] B [mm] L [mm] Line 100 Line 120 Line 125 Line 150 ...2...
  • Page 18 Fan does not run Contact of the S switch or the pull cord switch is CLOSED Fan runs Line 100/120/125/150 S Contact of the S switch or the pull cord switch is OPENED Line 100/120/125/150 T Fan does not run...
  • Page 19 Line 100/120/125/150 Н Line 100/120/125/150 SН Fan does not run Contact of the S switch or the pull cord switch is CLOSED Humidity exceeds set point Fan runs Contact of the S switch or the pull cord switch is OPENED...
  • Page 23 Quality Inspector’s Stamp Sold by (name and stamp of the seller) Manufacture Date Purchase Date...
  • Page 24 Still Line e K1 www.blaubergventilatoren.de B12060_220EN-01...

Table of Contents