B
I
OOSTER
NSTALLATION
Refer to the OEM manufacturers installation instructions
Boosters and accumulator tanks should be fed with AMBIENT water only. To avoid condensation and premature
equipment failure, do not install the water booster assembly in the refrigerated water supply circuit.
To prevent pressure drops in the water supply line, use 3/8" (9.5 mm) ID supply lines only. Limit the amount of flow
restrictions s.a. shut-off valves, manifolds and/or fittings.

Water Connection

3/8 in. (9.5 mm) SAE male flare fitting on the dispenser.
The Quest Elite QLT HC 2000 series Juice Dispensing machine is designed to dispense juice at a high flow rate. It
is very important that the incoming water line is dedicated for the unit, or at least does not have other machines
connected which could cause a water surge, i.e., a dish washing or coffee machine.
NOTE: The unit should be fed by an insulated chilled water line from the soft drink beverage system. To
achieve both optimal brix control and sanitation, assure that the incoming water pressure is at
least 60 psi (4.2 bar) dynamic coming from the water booster system.
IMPORTANT: The water supply should be consistent with proper water quality standards (neutral pH of 7.0 to
8.0), and should not be connected to a water softener. It is the installer's responsibility to ensure
that all water connections to the dispenser are sized, installed with adequate backflow protection
and maintained to comply with Federal, State, and Local Laws.
A. Secure the 3/8" (9.5 mm) swivel nut on the flexible supply tubing to the water inlet located at the rear of the dis-
penser. Make sure that the flared gasket is used (flared gasket P/N 311304000 is included with the installation kit).
B. When securing flare nut, use backup wrench on male side of the inlet fitting (unit side) to prevent twisting of the copper tube
inside the unit and/or possible damage to the water strainer/solenoid.