7. Push the Cancel/Pour button until approx. 300 ~ 350 ml of water has dispensed
into the RVC water chamber.
8. Place the RVC onto a flat surface and read both water and syrup volumes.
9. With standard Orange Juice, the Ratio must be 5 to 1 with a maximum of 5.2 and
a minimum of 4.8
10. If ratio too low: Increase water flow.
To correct a low ratio, increase the water flow. Turn the water flow control screw to
the right (clockwise) ¼ turn. Check the ratio again by repeating Steps 1 to 3 with a
new sample in the RVC.
11. If ratio too high: Reduce water flow.
Turn the water flow control screw to the left (counterclockwise) ¼ turn. Check the
ratio again by repeating Steps 1 to 3 with a new sample in the RVC.
12. Replace the mixing chambers and reconnect them to the concentrate pouch
tubes.
13. Reinstall the parts in the juice dispenser.
14. Sanitize the syrup splitter and put it aside in a safe and clean location.