Replaceable Parts For P100E3 Nodes; P100E3 Node Specifications; Table 2-3. Replaceable Parts For P100E3 Nodes - Quantum ActiveScale P100E3 Support Manual

With os 6.0.2 software
Hide thumbs Also See for ActiveScale P100E3:
Table of Contents

Advertisement

ActiveScale™ P100E3 Support Guide
Table 2-2. P100E3 Node control panel LED and button descriptions (continued)
Number
Name
4
USB 2.0 port
5
Fault
6
LAN1
7
LAN2
8
HDD Activity

2.1.2 Replaceable Parts for P100E3 Nodes

The following table lists all of the replaceable components for a Storage Node.

Table 2-3. Replaceable Parts for P100E3 Nodes

Replaceable part
12 TB HDD with carrier
14 TB HDD with carrier
480 GB SSD with carrier
PSU module, 400 W
Storage Node chassis
1.Only hot swappable after decommissioning.

2.1.3 P100E3 Node Specifications

The following table lists the system specifications for an individual P100E3 node.
Description
Connects to a USB device.
Indicates items that require attention. • Solid amber— Can indicate the
Indicates Link or LAN1 access.
Indicates Link or LAN2 access.
Indicates activity on the hard drive
when flashing. The three HDD
activity LEDs correlate to the rows of
drives in the tray and whether or not
there is activity there.
Hot
swappable?
1
Yes
Yes
Yes
Yes
--
10
LED action
N/A
following:
– Critical Failure—critical fan,
voltage, temperature state
– Non-Critical Failure—non-
critical fan, voltage,
temperature state, CPU thermal
trip, DC off. Also on when the
SEL is full.
• Off—SEL cleared or last pending
warning or error has been de-
asserted.
• Solid blue—Link
• Blinking blue—LAN access (off
when there is traffic).
• Solid blue—Link
• Blinking Blue—LAN access (off
when there is traffic).
• Blinking blue—Hard disk drive
access (only on-board SATA
port).
• Off—No access (non-SAS)
Part number
9-07182-01
9-07186-01
9-05677-04
9-07141-01
9-07143-01