Wall Mounted and LSP Duct Type Functions
1.3

Airflow Direction Control

Applicable
CTKS25/35/50/60/71TVMG
CTKB25/35/50/60TVMG
Models
Power-Airflow
The large flap sends a large volume of air downward to the floor and provides an optimum
(Dual) Flap(s)
control in cooling and dry operation.
Cooling/Dry
During cooling or dry operation, the flap retracts into the indoor unit. Then, cool air can be blown
far and distributed all over the room.
Wide-Angle
The louvers, made of elastic synthetic resin, provide a wide range of airflow that guarantees
comfortable air distribution.
Louvers
Auto-Swing
The following table explains the auto-swing process for cooling, dry and fan:
3-D Airflow
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motions are alternated and the airflow
direction changes in the order shown in the following diagram.
(1) The vertical blades (louvers) move from the right to the left.
(2) The horizontal blades (flaps) move downward.
(3) The vertical blades (louvers) move from the left to the right.
(4) The horizontal blades (flaps) move upward.
47
Series
Cooling / Dry
25/35/50 class
40°
15°
60/71 class
50°
Flap (up and down)
Fan
65°
(R23144)
(R21050)
10°
30°
25°
65°
65°
(R23145)
(R21653)
(1)
(2)
(3)
Louver
(right and left)
(R24915)
80°
(R11404)
(4)
(R13554)
Part 4 Functions and Control
SiSG121917E