Set the operation mode switch (SW2) and the NIGHT QUIET mode setting switch (SW6-1 or
SW5-5) as described below.
5.3.4 ECONO-mode-proof Setting
Outline
You can make ECONO mode ineffective on the outdoor unit.
Operation
The ECONO mode can be switched over between effective and ineffective by pressing the
forced operation ON/OFF switch (SW1) on the outdoor unit and wiring error check switch (SW3)
on the outdoor unit at the same time and holding them for 5 seconds while the compressor is
stopped. The LEDs are lit in turn for 15 seconds to show the ECONO mode status.
The factory setting is effective.
Part 7 Trial Operation and Field Settings
50/65/80 class
Unit limit
SW2
COOL
HEAT
Without limit
(factory set)
(R22671)
COOL
HEAT
11.0 A
(R22672)
COOL
HEAT
8.5 A
(R22672)
LED flashing order
3 or 4-room model
5-room model
SW6-1
ON
OFF
H
C
E
O
2
A
O
1
T
L
(R22639)
ON
OFF
H
C
E
O
2
A
O
1
T
L
(R22639)
ON
OFF
H
C
2
E
O
A
O
1
T
L
(R22640)
effective  ineffective
4  3  2  1
5  4  3  2  1
Field Settings
90 class
SW2
SW5-5
ON
OFF
(R22673)
R7000259
ON
OFF
(R22674)
R7000259
ON
OFF
(R22674)
R7000261
ineffective  effective
1  2  3  4
1  2  3  4  5