Electrical System Maintenance; Electrical System Safety; Servicing The Battery - Toro 31914 Operator's Manual

Commercial walk-behind traction unit 18hp pistol-grip hydro drive
Hide thumbs Also See for 31914:
Table of Contents

Advertisement

Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

Service Interval: Every 100 hours
Always keep the battery clean and fully charged. Use
a paper towel to clean the battery case. If the battery
terminals are corroded, clean them with a solution of
four parts water and 1 part baking soda. Apply a light
coating of grease to the battery terminals to prevent
corrosion.
Voltage: 12 V
Removing the Battery
1.
Park the machine on a level surface, disengage
the PTO, and engage the parking brake.
2.
Shut off the engine, remove the key, and wait
for all moving parts to stop before leaving the
operating position.
3.
Remove the battery as shown in
Figure
25.
24
Figure 25
g030988