Unit Specifications and Features

Air outlet
Louver
Operating Temperature
When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and cause the
unit to disable.
Room
Temperature
Outdoor
Temperature
NOTE :
Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may
attract condensation. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.
6
Indoor unit display
Installation part
Air inlet
Display panel
Fixed-Speed Type
Cooling Mode
17°C - 32°C
18°C - 43°C
-7°C - 43°C
(For models with low-temp cooling systems)
18°C - 52°C
(For special tropical models)
To further optimize the performance of your unit, do the following:
Keep doors and windows closed.
Limit energy usage by using TIMER ON and TIMER OFF functions.
Do not block air inlets or outlets.
Regularly inspect and clean air filters.
MANUAL
OPERATION TIMER
OPERATION
: This lamp lights when the system is operating.
TIMER
: This lamp lights when the system is being controlled by timer
DEF / FAN
: This lamp lights when the system is in fan mode.
ALARM
: This lamp lights when the system is abnomal operation.
Abnormal Operation
1
Room sensor has a problem
2
Freeze sensor has a problem
3
Water level sensor has a problem (Option)
Dry Mode
10°C - 32°C
11°C - 43°C
18°C - 43°C
18°C - 52°C
(For special tropical models)
DEF./FAN
ALARM
Infrared receiver
LED Light
Blink 5 times
Blink 6 times
Blink 8 times
MCXE-IOM