Manual, it may entail cancellation of that you follow them carefully. protest to the last carrier of the warranty and liabilities by The Trane The Trane Company assumes no goods within 72 hours of delivery. Company.
Contents General Information Typical Installation Location and Preparation of Units Unit Installation Connection of Refrigerant Tubing Condensate Drain Piping Electrical Installation Remote Control Installation Typical Wiring Diagram Dimensional Data Notes MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:44 PM Black...
Typical Installation Return air grille Supply air grille contains air filter Adjustable louvers direct air Ceiling mounted Indoor unit Refrigerant tubing/wiring Supply air grille Outdoor unit Adjustable louvers direct air Drain Return air grille contains air filter Floor mounted Low wall mounted Note: For models MCX 042, MCX 048, MCX 060 there are only two styles of installation: under ceiling and low wall MS-SVN015-EN...
Location and Preparation of Units 1. Select an appropriate position 6. Recommended service that allows every corners of the clearance as shown in figure room to be uniformly air 2, 3 and 4. conditioned and where it is easy to route the refrigerant tubing. 2.
Unit Installation 6. Unscrew at the return grille Indoor Unit (Figure 7). 1. Select a location to route tubing, wiring and drain pipe between the indoor and outdoor units. 8.5"(215) 2. Make a hole in the wall using a key hole saw or hole-cutting drill attachment.
Connection of Refrigerant Tubing The indoor unit refrigerant line When reaming, hold the tube end A good flare should have the connections are flared both 50 Hz downward and be sure that no following characteristics: and 60 Hz. Installation brazing, leak copper scraps fall into the tube.
Page 8
Connection of Refrigerant Tubing 5. Insulate the entire gas line. Connection Connecting the unit with 6. Do not allow uninsulated liquid brazing procedure line to come in direct contact 9. For proper connection, align the (Only for MCX 042-060) with bare gas line. union tube and flare tube straight 7.
Condensate Drain Piping The drain hose should run When the drain hose is placed straight down the wall to a in the room, insulate the hose level where the runoff will not with foam polyethylene to stain the wall. avoid damage to the ceiling or furniture.
Electrical Installation All wiring and grounding must Indoor Unit comply with local electrical codes. Remove the right side panel and return grille (see previous 1. Wiring instructions), to access the terminal Important Safeguards: base. - Check the unit nameplate Pass the system wiring for electrical rating.
Remote Control Installation Locate and attach the wireless remote control and wired control as follows: 1. Do not place the control and 90.0 the remote control near heat sources or expose to the 61.0 direct rays of the sun. 14.5 14.5 2.
Typical Wiring Diagram MCX512-042GB5 (50 Hz) MCX512-536GB (50 Hz) MCX512-536G1 (60 Hz) INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “R”, 4 SPEED 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2. TEMPERATURE SENSOR LOCATED IN RETURN AIR STREAM GRN/YL ROOM FREEZE DISPLAY SWEEP MOTOR (OPTION)
Page 13
Typical Wiring Diagram MCX512-536GB (50 Hz) Standard Models MCX512-536G1 (60 Hz) Standard Models INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “R”, 3 SPEED MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:45 PM Black...
Page 14
Typical Wiring Diagram MCX042-060GB (50 Hz) Standard Models MCX042-060G1 (60 Hz) Standard Models INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “R”, 3 SPEED 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2. TEMPERATURE SENSOR LOCATED IN RETURN AIR STREAM GRN/YL FREEZE ROOM DISPLAY INFRARED RECEIVER...
Page 15
Typical Wiring Diagram MCX512-042GB5 (50 Hz) MCX512-536GB (50 Hz) MCX512-536G1 (60 Hz) INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “W”, 4 SPEED 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2. TEMPERATURE SENSOR LOCATED IN RETURN AIR STREAM GRN/YL ROOM FREEZE DISPLAY SWEEP MOTOR (OPTION)
Page 16
Typical Wiring Diagram MCX512-536GB (50 Hz) Standard Models MCX512-536G1 (60 Hz) Standard Models INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “W”, 3 SPEED MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:45 PM Black...
Page 17
Typical Wiring Diagram MCX042-060GB (50 Hz) Standard Models MCX042-060G1 (60 Hz) Standard Models INDOOR UNIT, COOLING ONLY WITH CONTROL TYPE “W”, 3 SPEED 1. FREEZE SENSOR LOCATED ON EVAPORATOR COIL 2. TEMPERATURE SENSOR LOCATED IN RETURN AIR STREAM GRN/YL FREEZE ROOM DISPLAY WIRE DISPLAY...
Page 18
Typical Wiring Diagram MCX512-536GB (50 Hz) MCX512-536G1 (60 Hz) INDOOR UNIT, COOLING/HEATER WITH CONTROL TYPE “R”, 4 SPEED MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:45 PM Black...
Page 19
Typical Wiring Diagram MCX512-536GB (50 Hz) Standard Models MCX512-536G1 (60 Hz) Standard Models INDOOR UNIT, COOLING/HEATER WITH CONTROL TYPE “R”, 3 SPEED MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:45 PM Black...
Page 20
Typical Wiring Diagram MCX042-060GB (50 Hz) Standard Models MCX042-060G1 (60 Hz) Standard Models INDOOR UNIT, COOLING/HEATER WITH CONTROL TYPE “R”, 3 SPEED MS-SVN015-EN MS-SVN015-EN.p65 2/17/09, 4:45 PM Black...
Page 24
Trane Stocking Location: Bangkok, Thailand www.trane.com For more information, contact your local district Trane has a policy of continuous product and product data improvement and reserves the right to change office design and specifications without notice. MS-SVN015-EN.p65 2/17/09, 4:45 PM...