Trane MCC 518 ZB Owner's Manual
Trane MCC 518 ZB Owner's Manual

Trane MCC 518 ZB Owner's Manual

Cassette split system
Hide thumbs Also See for MCC 518 ZB:

Advertisement

Split System,

18,000 - 48,000 Btu/h
Underceiling Type
MCC Series 50 Hz
Models
Cooling Only
MCC 518 ZB
MCC 524 ZB
MCC 530 ZB
MCC 536 ZB
MCC 048 ZB
October 2007
MCC-SVU02A-EN

Advertisement

Table of Contents
loading

Summary of Contents for Trane MCC 518 ZB

  • Page 1: Split System

    Split System, 18,000 - 48,000 Btu/h Underceiling Type MCC Series 50 Hz Models Cooling Only MCC 518 ZB MCC 524 ZB MCC 530 ZB MCC 536 ZB MCC 048 ZB October 2007 MCC-SVU02A-EN...
  • Page 2: General Information

    Warnings are provided at appropriate you follow them carefully. The Trane described in Owner Manual, it may places in this manual to indicate to Company assumes no liability for the...
  • Page 3 Contents System Operation MCC-SVU02A-EN...
  • Page 4: System Appearance

    System Appearance Indoor Unit Drain Pipe Front Panel Air Outlet Return Air Display Lights Air Filter (Inside) Remote Control High Pressure Copper Tube Remote Control Holder Connecting Wire between Indoor Unit & Outdoor Unit Low Pressure Copper Tube Drain Pipe Air Inlet Wire Refrigerant Tube...
  • Page 5: Control Operation

    Control Operation Infrared Remote Control Name and Function of buttons 1. Infrared Signal Transmitter Transmits the signal to indoor unit 2. System Mode Displays the current operating mode. In cooling only it will operate in Cooling - Dry (Dehumidification) - Fan mode consectutively 3.
  • Page 6: Remote Control

    Indicators on Infrared Remote Control System Operating Selection FAN Only System Operation DRY System Operation Setting STOP Timer - Press POWER button (the display - Press POWER button (the display You can set the STOP timer to stop panel shows the previous settings). panel shows the previous settings).
  • Page 7 Setting Auto-Start Timer You can set the stop timer to start... - When the air-conditioner is in the standby mode, press the TIMER button and the air conditioner will SWING enable start timer to automaticall SLEEP Mode swing turn on the unit This feature automatically adjusts the - Press the HOUR button to set the temperature setting to provide...
  • Page 8 Display Unit Four lamps on the display unit show operating status. Infrared Receiver Emergency Operation Key POWER RUN TIMER PROTECT Emergency Operation Key - This button ca be used as emergency operation when remote controller is not available POWER LED - This lamp lights for showing power on/off status RUN LED - This lamp lights for showing operating status of the...
  • Page 9: Maintenance

    Maintenance Replacing Air Purifying Filter Cleaning the Air Filters (Option) Before inspection and maintenance of the unit, always set the main Replacement of air purifying filters. power switch to “OFF” to cut off (recommend once every three months) power supply. - Swing up the grille until the latches click into the positions.
  • Page 10: System Operation

    System Operation - The temperature should not be - Check electrical system (voltage set lower than what you need. and frequency). Use the proper This would result to increase power supply indicated on the unit energy cost. to operate the air conditioner and - Clean the air filter every week for only fuses with specified capacity.
  • Page 11: Troubleshooting

    Troubleshooting Check the following before contact the service man. You may find the solution to your problems. After checking, if it still does not operate, please contact your local dealer. unit while running. MCC-SVU02A-EN...