Motor lead pigtail splice fir 5/8 kv non-shielded and shielded cables ribbon or wire and unishield cables, cable size range, feeder 8 awg-500 kcmil, motor lead 10 awg-500 kcmil, copper conductors (12 pages)
Assembly of the 68, 80, 100 position mdr metal junction shells for pleated foil cable and mdr plug. (2 pages)
Summary of Contents for 3M SafeLok Anchorage 4011
Page 1
Operations and Instruction Manual SafeLok Anchorage - Model # 4011 IM-0051 REV A Portable Concrete and Steel Anchorage Connector ANSI Z359.1-07 5,000 lbs / 22kn Made in the USA The 3/4” Fall Protection SafeLok is to be used in concrete or steel. DO NOT use in wood or any other substrate.
Page 2
APPLICATIONS USE: The SafeLok anchorage connector is designed for fall protection, horizontal or vertical lifeline systems, restraint, work positioning, tie back anchors, and rescue. REQUIREMENTS Follow all manufacturer’s instructions with this device. Only trained personnel should install, maintain, inspect and use this product and its components or other personal protective equipment in conjunction with this product.
Page 3
Do not work above anchorage point Anchorage connector Shock absorbing lanyard Work Surface Consider D-ring slide and deceleration distances from shock absorbers and make sure you obtain a minimum 2’ clearance. Obstruction/Deck/Floor/Ground Swing Fall Swing fall can occur when the worker is not directly under the anchorage point.
GENERAL INSTRUCTIONS AND CARE Important Warnings This product is to be used by trained fall protection personnel only. It is to be anchored in accordance with manufacturer’s requirements. All persons using this equipment must read and understand all instructions. Failure to do so may result in serious injury or death. If a fall occurs, the SafeLok must be disposed of according to the manufacturer instructions.
Page 5
ACTIVATING THE TOGGLE BAR Set the Toggle Bar in the insertion position (Dia. A ). Place your thumb on the Cap of the Activator Cable. Push the unit through the hole while pressing on the Cap. As the unit passes through the hole, the Toggle Bar will flip to the open position.
Page 6
INSTRUCTIONS FOR USE IN CONCRETE Use For Fall Protection Only Drill a 3/4” diameter hole . Drill hole in the center of core hollow. Never drill hole closer than 6” to any edge or corner. Always inspect a previously drilled hole for deformation. Drill another proper hole if needed.
Page 7
PLACEMENT Push the unit downwards until the Only when the unit is activated Spring fully compresses. Push on in the open position is it safe Unit in position. insertion Activator Cap to force the Toggle Bar for load bearing. into open position. REMOVAL Unit inserted.
Page 8
INSTRUCTIONS FOR USE IN STEEL Use For Fall Protection Only Drill a 3/4” diameter hole . Drill center of hole at least 1-1/2” from any edge or corner. Always inspect a previously drilled hole, make sure the hole is round and a true 3/4”...
Page 9
PLACEMENT IN STEEL Unit in insertion position. The center of the hole must be drilled at least 1-1/2” from any edge. Push the unit downward until the Spring fully compresses. Pushing on Activator Cap will force the Toggle Bar Only when the unit is activated in the into open position.
Page 10
SafeLoks may be used for shear and tensile loads up to a 90 degree bend. Anchors are authorized to be used as positioned in diagrams A and B. NEVER place a anchor as shown in diagram C.
Page 11
Date Corrective Action Name of Inspector Signature FOR MORE INFORMATION In United States, contact: Website: www.SafeWaze.com Technical Assistance: 1-800-560-1094 Fax: 1-800-560-1275 3M Occupational Health and Environmental Safety Division 4451 Raceway Drive South West Concord, NC 28027 Customer Care Center: 1-800-328-1667...
Need help?
Do you have a question about the SafeLok Anchorage 4011 and is the answer not in the manual?
Questions and answers