Controls And Adjustments - Hoshizaki Commercial Series Service Manual

Refrigerated kitchen equipment
Hide thumbs Also See for Commercial Series:
Table of Contents

Advertisement

https://appliancetechmanuals.com

2. Controls and Adjustments

a) Default Settings
1. Temperature Setting: Refrigerator: 36°F (3°C).
2. Temperature Display Scale: F.
b) Temperature Setpoint
The temperature setpoint is the value for the average cabinet temperature. The
temperature differential for the compressor to turn on and off is ±3°F (±1.7°C) of the
temperature setpoint for refrigerators and +2°F/-3°F (+1.1°C/-1.7°C) of the temperature
setpoint for freezers. For example, for a refrigerator temperature setpoint of 36°F (2°C),
the compressor comes on at 39°F (3.7°C), and the compressor goes off at 33°F (0.3°C).
If necessary, adjust the temperature setpoint as follows:
1) Press and hold the upper or lower button briefly, then release. The current temperature
setpoint flashes. Press the upper or lower button until the desired value is displayed.
After a few seconds, the display returns to the current cabinet temperature and the
temperature setpoint is saved.
• For refrigerators, the temperature setpoint is adjustable between 33°F and 52°F
(-1°C and 11°C). Factory default is 36°F (3°C).
• For freezers, the temperature setpoint is adjustable between -16°F and +12°F
(-27°C and -11°C). Factory default is -4°F (-20°C).
c) Changing the Temperature Display Scale (F or C)
To change the temperature display scale, press the upper button for 5 seconds. The
current setting is displayed. Press the upper button to change the scale. After a few
seconds, the display returns to the current cabinet temperature and the setting is saved.
The factory default is F.
Note: Pressing the upper and lower button at the same time for 5 seconds (or until "- - -"
appears on the display module), turns the compressor, condenser fan motor, and
evaporator fan motor (freezer) off. To turn the unit on again, press the upper and
lower button together for 5 seconds until the cabinet temperature appears on the
display module.
d) Manual Defrost
Manual defrost may be initiated by pressing and holding the lower button for 5 seconds.
"dEF" appears in the display. For further details, see "II.B.1. Sequence Cycles and
Shutdown."
Freezer: -4°F (-20°C).
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commercial reach-in

Table of Contents