Installation Indoor Unit - Trane MXW Installation Operation & Maintenance

R410a split system - wall unit heat pump - up to 16.9 seer 9,000 - 18,000 btu/hr
Table of Contents

Advertisement

Wall Mounting Frame
1. Level frame with plumb line or
spirit level. Since the drain outles
is on the left side, it is best that the
left side be lower when adjusting
the frame on the wall.
2. Use screws to secure the frame
onto the wall.
3. After completing installation, tug
on the frame to see if it is firmly
secured to wall. The wall
mounting frame should be able to
support the weight of an adult (60
kg) and the fixing screws should
bear stress evenly.
Wall Opening and Wall Pipe
1. After deciding the position of the hole for the fitting pipe according to
Figure 6, drill a slanted hole (65 mm dia.)
2. To avoid damages to the fitting pipe and to the cable passing
through the wall opening, and to protect it also from rodents, it is
recommended to install a protective wall pipe in a downward slant.
Drain Pipe
1. The flexible drain pipe must be in a slanted position to allow for
smooth draining of the water.
2. Be careful not to twist, bend or distort the drain pipe and do not
immerse the outlet in water.
3. The extended section of the flexible drain pipe that passed through
the indoor unit must be wrapped in thermal insulation material.

Installation Indoor Unit

Indicated at the
central position
Wall
More than
150 mm
from wall
Left side
65mm
(wall hole for
rear exit - pipe)
23
Place level
meter here
screws
Figure 6
Indoor
Protective
Pipe
Bending
Wall
More than
150 mm
from wall
Right side
65mm
(wall hole for
rear exit - pipe)
Outdoor
65mm
Twisting
Do not
immerse in
water
MS-SVX10A-EN