Installing Indoor Unit
Fitting pipe can come four directions, that is, right,
rear right, left and rear left.
1. When laying the pipe line on either the left or right
side, cut out extra part as needed to accommodate
piping at the tube exit plate on the base of the unit.
See Figure 9.
(1) When only drawing out the power line, cut
Extra Part 1.
(2) When drawing out the connecting pipe
and the electric line, cut Extra Parts 1 and
2 (or 1, 2, 3).
2. Pull out the fitting pipe from bottom case. Use
adhesive tape to bind the fitting pipe, electric
cable and drain hose and then pass them
through the fitting pipe hole. See Figure 10.
3. Hang the brackets at the rear side of the indoor
unit to the hooks on the wall-mounting frame.
Shift the unit left and right to verify that it is
steady. See Figure 11.
4. The installation height of the indoor unit must be
at least 2.0 m.
Installation Indoor Unit
25
Fitting
pipe for
gas side
Extra Part 3
Extra Part 2
Heat
Extra Part 1
Insulation
Figure 9
Right
Right Rear
Figure 10
Support
Hook
Mounting
Plate
Figure 11
Power
connection
cord
Drain
pipe
Fitting pipe
for liquid
Wrapping
side
tape
Left
Left Rear
Mounting
Plate
MS-SVX10A-EN