6.1.4 Run Source and Sequence Input Responsiveness: b1-02, b1-06, b1-07

Run Source: b1-02
J
User
User
Constant
Number
b1-02
Constant b1-02 is used to select the source of the run command.
D
When a control circuit terminal (external terminal) is set, the Unit operates with 2-wire forward run/
D
stop and reverse run/stop control. (When the Unit has been initialized for a 3-wire control or a multi-
function input is set to 0 (3-wire sequence), the Unit operates with 3-wire run, stop and forward/reverse
controls.)
When using winding change function, set b1-02 to "5" (winding change sequence).
D
Settings
D
Setting
0
1
2
3
4
5
Sequence Input Responsiveness (Reading Twice): b1-06
J
User
User
Constant
Number
b1-06
Set the responsiveness of the control inputs (forward/reverse run and multi-function inputs)
D
Settings
D
Setting
0
1
Set the responsiveness to match the type of control inputs being used. Use a setting of 1 if there is one
D
or more contact inputs.
Operation after Switching to Remote Mode: b1-07
J
User
User
Constant
Number
b1-07
Set the interlock operation to be used after switching from local mode (operation from Digital Opera-
D
tor) to remote mode (operation according to control circuit terminal).
Settings
D
Setting
0
1
Change
during
during
Name
Opera-
tion
Operation method selec-
tion
Digital Operator
Control circuit terminals (external terminals)
Transmission
Optional Card
MEMOBUS transmission (for CP- -717)
Winding change sequence
Change
during
during
Name
Opera-
tion
Read sequence input
twice
Two scans every 2 ms (Use when connecting transistor outputs.)
Two scans every 5 ms (Use when connecting contact outputs or switches.)
Change
during
during
Name
Opera-
tion
Operation selection after
switching to remote
mode
No operation even if RUN signal is ON after switching to remote mode. (Operation will start if
the RUN signal turns OFF and then back ON after switching to remote mode.)
Operate according to the RUN signal after switching to remote mode.
- 9
Valid Access Levels
Setting
Setting
Factory
Factory
Unit
Open Loop
Range
Setting
Vector
0 to 5
- -
1
Run source
Valid Access Levels
Setting
Setting
Factory
Factory
Unit
Open Loop
Range
Setting
Vector
0 1
- -
1
Function
Valid Access Levels
Setting
Setting
Factory
Factory
Unit
Open Loop
Range
Setting
Vector
0 1
- -
0
Function
6.1 C ommon Settings
Flux Vector
Q
Q
Flux Vector
A
A
6
Flux Vector
A
A

Advertisement

Table of Contents
loading

Table of Contents