Rapid Shape D50+ Translation Of The Original Operating Instructions page 80

Table of Contents

Advertisement

Operating Instructions D50+ | P50+ | SHERAprint 50
Preparation
Execution
Rapid Shape GmbH │ DOCR000438
Proceed as follows to prepare for calibrating the exposure unit:
1. Wear protective gloves on your hands.
2. Open the machine.
3. Remove the collection basket and place it on a paper towel.
Caution! Watch out for material dripping from the collection
basket. Hold the basket at a slight angle towards the back to
prevent material from leaking out. Also place a paper towel
directly underneath the basket opening.
4. Ensure that the build platform, knife drip guard and knife, if
inserted, are clean. If liquid material is found adhering to the
components, remove them first from the machine before
removing the material reservoir.
5. If a material reservoir is inserted in the machine, pull the
reservoir out of the machine. To do so, press the reservoir down
slightly and then pull it out of the machine. Store the reservoir in
a reservoir box.
6. Now insert the calibration device into the machine.
7. Take the sensor in your hand and remove the black rubber cap
from the sensor head, if present.
8. Then place the sensor head in the calibration device with the
glass surface facing downwards. The sensor cable must be
pointing in the direction of the machine opening.
9. Plug the USB connector of the sensor into the USB port on the
front of the machine.
10. Put on the UV safety goggles.
11. Now open the calibration menu: Press the «Calibration» button
in the main menu.
For calibrating the exposure unit, please proceed as follows:
1. Press the «Yes» button to confirm that you have connected the
sensor to the machine.
2. Press the «Yes» button to confirm that you have placed the
sensor head in the calibration device. Calibration then starts
immediately and is carried out automatically.
3. Save the new calibration parameters by pressing the «Save» and
«Okay» buttons. You will then be returned to the main menu.
4. Disconnect the USB connector of the sensor from the USB port.
5. Remove the sensor head out of the device and put it back into
the packaging.
6. Remove the calibration device from the machine.
The calibration is finished.
80 │ 96

Advertisement

Table of Contents
loading

This manual is also suitable for:

P50+Sheraprint 50

Table of Contents