Stopping The Generator - Hyundai DHY6000SE/LR Manual Manual

Diesel generator
Hide thumbs Also See for DHY6000SE/LR:
Table of Contents

Advertisement

- Connect the positive and negative charging lead clips to the correct poles of the battery.
- If you try to charge a large capacity battery, which is at a low voltage, excessive current
flow may occur. This may result in the fuse for the 12v DC blowing.
- Do not use 12V DC and 230V AC at the same time.
Battery Charging
- Battery vents contain explosive gas. For this reason, keep sparks, flames and cigarettes
away from the battery. To prevent from creating a spark near the battery always connect
the charging cables to the battery first and only then to the generator. When disconnecting,
you should disconnect the cables at the generator first.
- Charge the battery in a well ventilated area.
- Before charging, remove the cap from each cell of the battery and ensure the electolyte
level is correct.
- Stop charging if the electrolyte temperature exceeds 45⁰C.
6.3 Electrical appliances, particularly motor driven equipment, will have a very high start-
up current. The table below provides reference for connecting these appliances to the
generator.
Type
Wattage
Starting
Lighting
X1
Heating
appliance
Fluorescent
X2
lamp
Motor
X3-5
Driven
Equipment

7. STOPPING THE GENERATOR

1. Disconnect the load from the generator.
2. Turn off the main breaker switch.
Typical
Appliance
Rated
X1
Incandescent
lamp or
heating
appliance
X1-1.5
Fluorescent
lamp
X1-2
Refrigerator
or electric
fan
14
Example
Appliance
Starting
Incandescent
100VA
lamp 1000w
(w)
Fluorescent
80VA (w)
lamp
Refrigerator
450-
150w
750VA
(w)
Rated
100VA
(w)
40 -60VA
(w)
150-
300VA
(w)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dhy6000se/lr-3

Table of Contents