ICT PRT-PSU-DIN-4A Installation Manual page 35

Table of Contents

Advertisement

Electrostatic discharge (EN 50130-4 ed. 2, EN 61000-4-2 ed. 2)
Contact discharges ± 6 kV, Air discharges to ± 8 kV
Radiated electromagnetic fields (EN 50130-4 ed. 2, EN 61000-4-3 ed.3)
Conducted disturbances induced by electromagnetic fields (EN 50130-4 ed. 2, EN 61000-4-6)
Fast Transient bursts (EN 50130-4 ed. 2, EN 61000-4-4 ed.2)
To the AC mains supply lines applied disturbance signal voltage level 2 kV both polarities for 1 minute. To other
supply / signal lines applied by the capacitive clamp injection method disturbance signal voltage level 1 kV for
both polarity for 1 minute.
Slow high energy voltage surge (EN 50130-4 ed. 2, EN 61000-4-5 ed.2)
To comply with EN 50131-1, EN 60839-11 Security Grade 4 and AS/NZS2201.1 class 4&5 Vibration Detection for
PreTamper Alarm, protection is provided by a DSC SS-102 Shockgard Seismic vibration sensor mounted within
the system enclosure. Alarm output is provided by a pair of non-latching, N.C. (normally closed), relay contacts,
opening for a minimum of 1 second on detection of an alarm connected in series with the 24Hr tamper input (TP)
on the PSU (or any other system input designated/programmed as a 24Hr Tamper Alarm).
This relay is normally energized to give fail-safe operation in the event of a power loss. Indication of detection is
provided by a LED situated on the front cover. The vibration sensor is fully protected from tampering by a N.C.
micro switch operated by removal of the cover.
Enclosure EN-DIN-24has been tested and certified to EN50131.
By design, the enclosures for all Integrated Control Technology products, EN-DIN-11, EN-DIN-12, EN-DIN-24-
ATTACK and EN-DIN-31, comply with the EN 50131 standards. Tamper protection against removal of the cover
as well as removal from mounting is provided by tamper switch.
Warning: Enclosures supplied by 3rd parties may not be EN50131-compliant, and should not be claimed as
such.
To comply with EN 50131-1 only one battery can be connected and monitored per system. If more capacity is
required a single larger battery must be used.
PRT-PSU-DIN-4A | Protege DIN Rail 4A Intelligent Power Supply | Installation Manual
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Protege prt-psu-din-4a

Table of Contents