- continuedfrompage7
Wire nut the black wire to the matching
circuit lead wire from the emergency
circuit breakerfrom load center in the
transferswitch.(Allcircuit wiresare color
coded
and
labeled
for
easy
identification).
UL approved wire
Iocknuts are included in installation kit.
Tracethe black (hot)wireyou havejust
connected backto the sameRomex cable(circuit)to find itsmating
white(neutral)wire.Wirenutthis wireto the matchingcircuitnumber
on the white (neutral)wire comingfrom the emergency load center.
Repeatthis processwith remainingcircuits to be poweredby the
generator.
NOTE: Bothgrounded andungrounded c onductors for eachcircuit
mustbe reconnected to the emergency loadcenterwiringusing
thesupplied wire Iocknuts.
Thechart belowshowsthe circuits provided in the loadcenter.
'llm[']L
l_,J
l,_v
,.i,_vl
i _,_rlvl i['_iv
1
1
1
1
1
1
1
1
1
1
3
3
5
5
5
3
5
5
5
NOTE:Circuitsto be movedmust be protectedby same size
breaker. F orexample, a 15 Ampcircuitin mainpanelmustbea 15
Ampcircuitin transferswitch.
13b.Installthe40 Ampor 70 Ampdoublepole
circuit breakerthat you have purchased
(See detailon page6) intomainelectrical
distribution panel. This circuit breaker
must be compatiblewith your main
electricaldistribution panel. It may be
necessary to repositionremainingcircuit
breakersor removecircuit breakersthat
havebeendisconnected to accommodate t he insertion of the 40 Amp
or 70Ampdoublepolecircuitbreaker.Connect white wireto the main
distributionpanelneutral bar.Connectgreenwireto main electrical
panelgroundbar.Connect t he black and red wiresto the 40 Ampor
70 Ampdoublepolecircuit breaker.
14. Recommended batteryis automotive type
Group 26 12V negative ground with
minimum350 CCAat 0° F (7 kW)or a
minimum525 CgAat 0° F(10 kW,13 kW
and 16 kW).The hold down clamp is
included. Connect positive (+) (red)
cable to positive (+) battery post.
Connect negative (-) (black) ground
cableto negative (-) batterypost.
WARNING S etthegenerator's AUTO / OFF / MANUAL switch to"OFF."
Turnoff utilitypowersupply to thetransferswitch.If the AUTO /
OFF ! MANUAL switch isnotsetto its"OFF"position, thegenerator
cancrankand startas soonas the battery cablesare connected.
WARNING I f theutilitypowersupply isnot turned off, sparking can
occurat thebatteryposts andcausean explosion.
NOTE: Dielectricgreaseshould be usedon batteryposts to aid in
the prevention o f corrosion.
NOTE: I n areas where temperatures regularlyfall below10° F
(-12° O) it is recommended that a pad type batteryheater be
installed to aid in coldclimatestarting.
15. Switchservicemaincircuit breaker t o "on" or closedposition.Switch
the circuit breakers in theemergency distributionpanelto the "on" or
closedposition.Switchthe generator m ainline circuit breaker t o the
"on" orclosedposition.Verify that the40 Ampor70 Ampdoublepole
circuit breakerthat was insertedin the main electricaldistribution
panelis switched to the "on"or closedposition.Placegenerator m ode
switch in the "AUTO"position.Verifythat fuel valve on rigid gas
piping is open. Perform stepsin Sections 2.1 through 2.5 of the
Installation & Owner's Manual p riorto testingthesystem.
16. Switchservicemain circuit breakerto "off" or open position.This
simulatesthe loss of utility power. T hegenerator s hould crankand
start within 20 seconds. Load transfer should occur within 10
secondsof generatorstart. To return systemto automatic mode,
switchservice main breaker t o "on" or closed position.Thissimulates
the returnof power f rom the utility. Thegenerator w ill runfor a short
cooldownperiodof severalminuteswhilethe entire systemstands
readyfor the nextpoweroutage.
NOTE: W henutilityvoltagesourceis lostbythe generator, the
system set lightwillflashrapidly.
17. A switch on the control
panel allows you to select
the day and time for the
systemto exercise. T oselect
a time and dayof the week
you must
perform the
Exerciser S witch
following sequenceat that time. Verifythat the Auto/Off/Manual
switchis setto "AUTO'.'
Holddownthe "Set Exercise ]]me" switch until the generator s tarts
(approximately 1 0 seconds) a nd release. T hegenerator w ill start and
runfor approximately t welveminutesandthen shut downon its own.
Thegenerator i s nowsetto exercise onthat dayandat that time every
week. If the batteryis disconnected for anyreason the exercise time
mustbe reset.NOTE: Until t he exerciseris set, all thered LED's will
flashin theAutoor Manual m ode.
YourCARRIER HomeStandby
generatoris nowready!