The Mrp-4424; Features; Circuits - Fire-Lite Alarms MRP-4424 Manual

Agent release
Table of Contents

Advertisement

1.0 The MRP-4424

1.1

Features

Microprocessor-controlled
Power-limited on all circuits except Municipal Box
output
Alarm and trouble resound
Four Style B/D Initiating Device Circuits
Two Style Y/Z Notification Appliance Circuits
Two Style Y Release Circuits
General alarm and trouble relays
Optional module for 4 zone/function relays (4XZMF)
Optional transmitter module (4XTMF). Complies with
NFPA 72-1993 Auxiliary and Remote Station Fire
Alarm Systems
Optional volt/amp meter module (4XMMF)
Optional supervised remote annunciator (RZA-4XF)
Requires LED Interface Module (4XLMF)
Optional digital communicator (NOTI•FIRE 911A/
911AC)*
Complies with NFPA 72-1993 Central Station and
NFPA 72-1993 Remote Station Fire Alarm Systems
Supervisory Input Option
Complies with NFPA 72-1993 Proprietary Fire Alarm
System. (requires Potter #EFT-C McCulloh Transmitter
Designed for suppression standards NFPA 12, 12A,
and 12B
* Applications which require the NOTI-FIRE 911A/911AC or Potter EFT-C are not FM approved.
1.2

Circuits

Input Circuits
Detector Zone 1 (Style B/D)
Detector Zone 2 (Style B/D)
Abort (Style B/D)
Manual Release (Style B/D)
Output circuits - optional auxiliary relay module (4XZMF) tracks these four circuits.
Notification Appliance Circuit 1 (Style Y/Z)
Notification Appliance Circuit 2 (Style Y/Z)
Releasing Circuit 1 (Style Y)
Releasing Circuit 2 (Style Y)/Supervisory Input (Style B)
Front Panel Control Switches
Switch 1
Switch 2
Switch 3
Switch 4
Technical Manuals Online! - http://www.tech-man.com
Tone Silence
Alarm Silence
Alarm Activate
System Reset
MRP-4424
Document 15180
firealarmresources.com
Disable/enable controls per Initiating Device
Circuits
Last Event Recall
Battery/Earth fault supervision
Fuse protection on all Notification/Release Circuits
RMS regulated output power, 2.25 amps
7 amp/hour to 15 amp/hour battery options, up to 90
hours standby
Resettable and non-resettable regulated power
outputs
Extensive transient protection
Watchdog timer to supervise microprocessor (in-
cludes MICRO FAIL LED)
Output circuits protected against false activations
Slide-in zone identification labels
Steel cabinet 14.5" wide by 16" high by 5" deep
Dead-front dress panel option (DP-4XF)
Trim ring for flush mount between 16" center studs
(TR-4XRF)
Abort and manual release circuits
Cross-zone option
Delay timer (adjustable)
Three abort function options
Rev D
03/12/97
15180:D
5