3" min.
3" min.
PL vent manufacturer's
f i r e s t o p s p a c e r a n d
support
Fig. 14
#8 installing through the ceiling
Through the ceiling vent, follow PL vent manufacturers
recommendations when using wall and ceiling pass
through. note: do not place joints within wall pass-
throughs.
13
P61A Pellet Stove
venting
Storm collar
Flashing
3" min.
No insulation
or other
combustible
materials are
allowed within
3" of the pellet
vent pipe.
Unless specified
by the pipe
manufacturer
(See Page 7 for
corner installation
clearances)
3" min.
Fig. 16
Minimum flue vent
configuration
It is recommended that
outside air be installed with
this venting configuration to
reduce smoke and creosote
smell in the room in the
event of power failure.
Fig. 15
12" min. wall to outlet