Layout Drawing (Standard spec.)
Notes on the floor finished with tiles or glass
In the case where the floor is finished with tiles etc., screwing bolts into the floor when
installing the shampoo unit may cause a crack on the floor surface. Change the material of the
floor of the installation position to plywood, mortar, etc.
1 Mark the floor at the base outline and the chair mount frame installation position. Cut the tile
or glass along the outer edge of the pattern you traced on the floor. Remove the area of tile
or glass precisely over the installation position.
2 Place the plywood on the area where the tile or glass was removed. The floor height of the
plywood portion must be higher than that of the tile or glass portion. (2 to 3 mm)
Distance to the wall or the
furniture, etc.:
Min. 965 mm
(including working space 600 mm)
* Spare fixing hole
When tapping the anchor bolt (or hex
tapping bolt) in the spare fixing hole in
the mount base, check the plumbing
layout beforehand. Ensure there are no
pipes below this area.
30
10
35
180
214 (Mount base width)
140
750
Chair mount frame installation dim.
160
21
Distance to the wall or
the furniture, etc.:
Min. 760 mm
(including working space
600 mm)
Distance to the wall or the
furniture, etc.:
Right Min. 400 mm;
Left Min. 750 mm
(including walkway 500 mm)