Nortel DMS-100 Series Replacement Procedures page 37

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RMM
5
Replace the NT0X10 card using the procedure "Replacing a card." When you
have completed the procedure, return here.
6
If you were directed to this procedure from the Alarm Clearing Procedures ,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 7.
7
Send any faulty cards for repair according to local procedure.
8
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 9.
9
You have completed this procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
DANGER
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point at the top of each equipment rack, (Bay 0, 1, 2, and 3),
while handling circuit cards. This protects the cards against
damage caused by static electricity.
in an IOPAC RMM
1-5
NT0X10
(end)