11 Technical data
11
Technical data
External dimensions
▸ See installation instructions
Electrical connection
▸ See identification plate 1
11.1
Note for testing institutes
Placing thermocouples between the appliance door and the seal can cause lack of leak-
tightness and thus measuring errors.
The usable volume within the meaning of EN 50304 / EN 60350 is obtained with the
shelf guides disassembled.
General note
Maximum load capacity: 3 kg
11.2
Temperature measurement
The temperature inside the cooking space is measured when the cooking space is
empty according to an internationally accepted standard. Own measurements can be im-
precise and are not suitable for checking the accuracy of the temperature.
11.3
Product fiche
In accordance with EU Regulation No.: 66/2014
Brand
Type of appliance
Model designation
Mass of the appliance
Number of cavities
Heat source per cavity
Volume per cavity
Energy consumption in conventional mode
Energy consumption in hot air / forced convection
2
mode
)
Energy Efficiency Index per cavity
Measurement and calculation methods used
1
Required to heat a standardized load per cavity
)
2
Required to heat a standardized load per cavity
)
3
Measurement methods: see EU Regulation No. 66/2014, Annex II, Chpt. 1
)
60
1
)
3
)
1
–
–
Steam cookers
–
kg
–
–
l
kWh/cycle
kWh/cycle
–
–
60350-1:2016
V-ZUG Ltd
CS4T
35
1
Electricity
48
–
0.46
61.2
SN EN