Noise Criteria Curve - Mitsubishi Electric MSZ-RW25VG Service Manual

Indoor unit
Hide thumbs Also See for MSZ-RW25VG:
Table of Contents

Advertisement

4

NOISE CRITERIA CURVE

MSZ-RW25VG
FAN SPEED
Super High
90
80
70
60
50
40
30
20
10
63
125
250
BAND CENTER FREQUENCIES, Hz
MSZ-RW50VG
FAN SPEED
Super High
90
80
70
60
50
40
30
20
10
63
125
250
BAND CENTER FREQUENCIES, Hz
OBH902A
FUNCTION SPL(dB(A))
LINE
COOLING
42
HEATING
41
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
500
1000
2000
4000
8000
FUNCTION SPL(dB(A))
LINE
COOLING
45
HEATING
46
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
NC-10
500
1000
2000
4000
8000
MSZ-RW35VG
FAN SPEED
Super High
90
80
70
60
50
40
30
20
10
63
125
BAND CENTER FREQUENCIES, Hz
Test conditions
Cooling: Dry-bulb temperature 27 °C
Heating: Dry-bulb temperature 20 °C
6
FUNCTION SPL(dB(A))
COOLING
43
HEATING
42
NC-10
250
500
1000
2000
4000
Wet-bulb temperature 19 °C
INDOOR UNIT
WALL
1m
0.8m
MICROPHONE
LINE
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
8000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msz-rw35vgMsz-rw50vg-e

Table of Contents