Installation; General Instructions; Installation Instructions For Pump Drive With Sae Flange And Rdb Coupling - DANA BREVINI BZ1-204 Installation And Maintenance Manual

Pump drives
Table of Contents

Advertisement

6 INSTALLATION

6.1 GENERAL INSTRUCTIONS:

Install the Product carefully following the steps listed below:
When mounting the pump drive, make sure that the breather, level and drain plugs are in the correct position. They will vary
in relation to the assembly position as indicated in paragraph "Configurations:" page 9.
The pump drive is normally supplied with a flange for coupling the hydraulic pumps.
The customer is responsible for installing suitable guards on the input shafts to protect couplings, universal joints, exposed
rotating parts, etc. according to the current safety standards in force in the country where the machine is used.
For pump drives installed in unprotected environments, use rust-inhibitor paint and protect the oil guard with water-repellent
grease.
NOTE:
Dana Incorporated advises against filling its products with oil prior to installation.
6.2 INSTALLATION INSTRUCTIONS FOR PUMP DRIVE WITH SAE FLANGE AND RDB
COUPLING:
Check that the spigots and coupling surfaces of the pump drive and the motor are clean and have not been dented.
Use grease or oil to lubricate the coupling spigots and the housing seat.
Position the outer ring on the flywheel and attach it using class 8.8 bolts.
NOTE:
use a hardened washer (R80) between the screw head and the ring to ensure correct tightening.
Tighten the bolts by applying torque as indicated in the paragraph "Bolt Tightening Torque Table:" page 23.
Check that the rubber blocks are perfectly inserted and are not incorrectly positioned; this may occur due to impacts during
transport or handling operations.
Install the pump drive making sure that the blocks fit into the impressions on the ring mounted on the flywheel and that the
spigot of the SAE housing correctly matches the motor spigot.
Insert all the bolts into the housing (class 8.8) and tighten them applying a torque as indicated in the paragraph "Bolt Tight-
ening Torque Table:" page 23
IMM-0007EN Pump Drives BZ
Dana Incorporated
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents