Xinje XP-18 Series Operating Manual page 20

Integral industrial controller
Table of Contents

Advertisement

There is one common point for basic unit transistor output
l
Power supply
The load circuit power supply should be steady voltage of DC5~30V.
l
Circuit insulation
The inside circuit of XP/XMP is insulated with output transistor by optical coupler.
l
Action indication
When driving optical coupling,LED lights,output transistor is ON.
l
Response time
From optical coupler driving (or cut) to transistor ON (or OFF), the time is below 0.2ms.
l
Output current
The current is 0.4A per point. But due to restriction of temperature going up, the total current
is 0.8A every four points.
l
Open current
Less than 0.1mA.
T o a v o i d b u r n i n g P L C b a s i c c i r c u i t
u s e s u i t a b l e f u s e f o r t h e l o a d
L o a d
Y * 4
L o a d
Y * 5
L o a d
Y * 6
L o a d
Y * 7
1 A
D C p o w e r
s u p p l y
D C 5 ~ 3 0 V
22

Advertisement