Titan atrato Instruction Manual page 26

Ultrasonic flowmeter range
Hide thumbs Also See for atrato:
Table of Contents

Advertisement

PIN 7:
26
Titan Enterprises Ltd ©2021
®
One of the following actions can be selected for each
pin configured as an Input:
Reset Total: Resets the total flow display to
zero. Equivalent to pressing the right hand
button on the flowmeter.
Reset Alarm: Clears output alarm conditions
active on any pins configured as alarms.
Reset Flowmeter: Initiates the equivalent of a
power-on reset of the meter.
Start/Pause Batch: Starts or pauses batch.
Equivalent to the display left button press in
(use rising or falling edge mode –
batch mode
DO NOT USE BOTH).
Reset Batch: In batch mode primes batch
system for new batch, resetting total to zero.
Equivalent to the display right button press in
batch mode.
Additionally, the input can be configured to act on a
rising or falling edge or both types of edge of the pulse
as the trigger.
Atrato_Instruction_Manual_0322