Lubrication And Maintenance Frequency - PROALL G Series Operator's Manual

Table of Contents

Advertisement

Lubrication and Maintenance Frequency

Table 7. Frequency Table
Maint.
Item
No.
Number
Points
1
1
2
2
2
2
3
1
4
2
5
1
6
1
7
1
8
1
8
1
9
1
9
2
10
1
11
1
12
1
13
1
14
1
14
1
14
1
1
Notes:
A. Refer to the Take Up Bearing section on page
7-1 for the correct gap setting.
B. Clear brush off debris and replace it if worn.
C. Purge the seal of mix residue immediately
after cleanup. Ensure the auger is running
while applying grease.
D. Check the return filter gauge. Ensure the
indicator shows green while the mix auger is
running. Refer to the Hydraulic Oil Filter
section on page 7-2.
E. Use SAE 30 weight oil or similar. For chain
oiler reservoir, fill chain oil to the base of the
filler neck. Fill as needed.
Rev.
1
Rear conveyor shaft grease, right
Front conveyor shaft grease, right and left
A
Rear conveyor shaft sensor gap check
Cement bin sump bearing grease
B
Chain brush check, left and right
Mix auger top bearing grease
Upper rear link grease
Lock arm grease
Lower rear link grease
Boom cylinder grease
Auger bottom bearing grease
C
Auger bottom bearing grease
Rear conveyor shaft grease, right
B
Cement bin sump brush check
D
High pressure hydraulic oil filter check
E
Maintain conveyor chain oil level
F
Hydraulic oil level check
G
Hydraulic return filter check
G
Hydraulic suction filter check
Hydraulic Oil Replace
Daily
F. Check that the oil level is showing in the sight
glass. Refer to Oil Specifications section on
page 7-1 for correct hydraulic oil.
G. The filter is located within the tank. A visual
inspection of the filter will be required to
ensure the filter is not clogged.
7-9
MX05001
Every
Every
Every
1
20
50
Load
Hrs
Hrs
3 March 2022
Every
500
Hrs

Advertisement