7. Lubrication and Maintenance

Maintenance

Regular maintenance and inspection will help
ensure
trouble-free
unnecessary downtime, and extend the life of
your ProAll Mobile Mixer. Keeping your mixer
clean and free from cement build-up helps to
maintain a good image to your customers. The
operator should perform a daily pre-operation
check, inspecting the truck and mixer for any
mechanical defects.

Speed Sensor

If equipped, ensure the GAP SPACE between the
speed sensors and shafts are set to 0.1 inch
(2.5mm). Speed sensors are located on the left-
hand side conveyor shaft at the rear of the
machine, on the cement auger drive shaft and
the colour feeder if equipped.
NOTE: The sensor must align with the center of
the shaft. Misalignment will result in sensor
reading errors.

Take Up Bearing

Ensure the take-up bearing has a ¼ inch gap
between the washer and tubing as shown in
Figure 18.
1/4 inch
Figure 21. Take-up bearing gap
Rev.
1
operation,
eliminate

Oil Specifications

Cleanliness

The hydraulic fluid must be maintained at ISO
Cleanliness Code 20/18/15 or better.

Hydraulic System

Your ProAll Mobile Mixer has been filled with
Petro Canada HYDREX™ XV to give you best all-
season
performance,
protection against wear
HYDREX™ XV is recommended for use in
equipment manufactured by Eaton (Vickers),
Cincinnati Machine, Denison, Racine, Sauer-
Danfoss and others.
Minimum Requirements for Replacement
Oil
In this hydraulic, the optimum viscosity range is
16 – 36 cSt (75 – 168 SUS), at normal operation
temperatures. Viscosity should never fall below
10 cSt (47 SUS.) At the lowest expected start-up
temperature, the viscosity – less than one
minute – should not exceed 1600 cSt (7500 SUS.)
7-1