7. Connect between the processor unit and CS-120A as follows.
Processor Unit
+24V_H
+24V_C
GND
CIF_TXD_H
CIF_TXD_C
CIF_RXD_H
CIF_RXD_C
SHIELD
Note: Echosounder should be connected to the processor unit directly.
8. Set the DIP switch as follows.
Input port
CIF1
NMEA 2/CIF 2
Note: Do not change the setting of S3-#4 (default: OFF). The hull unit may be
damaged if the setting is changed.
Note: If the CIF is select, baud rate should be changed to 2400 bps. See page
3-9 for detail.
POWER FOR CS-120A port
NJC-203-PM
1
2
3
CIF1 or NMEA2/CIF2
port
1
2
3
4
10
37-cores cable
10S1258
DIP switch setting
S3-#2: ON
S3-#3: ON
S3
DCON Board (10P6900 or 10P6900S)
CS-120A
J201
YEL
BRN
L
ORG
BRN
E
PPL
BRN
PP
NN
MM
JJ
KK
BB
EE
DD
Z
24V
0V
GND
TD-H
TD-C
RD-H
RD-C
GND
DSR-C
DSR-H
DTR-H
4-3