How to check the hull unit
1. Press the POWER ( ) switch on the control unit (for the display unit) to turn on
the equipment. Confirm that the lamps above the ON and
2. Confirm that the 5V and UP lamps on the raise/lower control box are lit.
3. Remove the cover of the raise/lower control box and use a multimeter to
measure the following voltages:
Terminal
Terminal No.
TB-C101
(1) – (2), (6) –(7)
(2) – (3), (7) – (8)
(1) – (3), (6) –(8)
4. In the raise/lower control box, set the TEST/NORMAL switch to TEST. Press
the [DOWN] switch to confirm that the transducer lowers. Also, while the
transducer is being lowered, check that the MD LED lights when the MD L.
SW kicks. Note that the MD L. SW does not stop the transducer when the
TEST/NORMAL switch is in the TEST position.
5. Press and release [DOWN] switch. Confirm that the transducer stops at the
moment the switch is released.
6. Press the [DOWN] switch again. Confirm that the transducer stops at the
moment the lower limit switch kick.
7. Confirm that the [UP] switch operators in a similar manner.
Transducer switches
Voltage
220 VAC
220 VAC
220 VAC
TEST
OFF
NORMAL
L.SW
UP MD DN
UP
Control unit (for the hull unit)
switches light.
5V
DOWN
3-3