"DATA2" Port

! IEC 61162-1/NMEA 0183 Ver. 1.5/Ver. 2.0 Output
Output Schematic Diagram (Talker)
DATA2
TD-A
TD-B
Output Drive Capability
Max. 10mA
IEC 61162-1 output is subject to the standard IEC 61162-1 First edition 1995-11.
Output Sentence is described on page 8 and 9. Each sentence is output at the interval
entered.

! NMEA 0183 Input

Input Schematic Diagram (Listener)
DATA2
RD-H
RD-C
Load Requirements
Isolation:
Input Impedance: 470
Max. Voltage:
Threshold:
Input Sentence is described on page 8 and 9.
20P8147
MJ-A6SRMD
J7
FL9
1
2
FL10
3
4
5
6
20P8147
MJ-A6SRMD
J7
1
2
FL8
3
4
FL7
5
6
opto coupler
15V
3mA (In case of FURUNO device talker connection)
16
18
17
U35
SN75ALS172
R76
470
1
4
PC-400
3
5
U28
CR14
1SS226
5. INITIAL SETTINGS
+5V
R63
2.2K