Bam Alert Table - JRC JSS-2150 Instruction Manual

Mf/hf radio equipment
Hide thumbs Also See for JSS-2150:
Table of Contents

Advertisement

Maintenance & Inspection
6.3.4

BAM alert table

The BAM alerts detected by this equipment are as follows.
Alert
Alert title
ID
3008 TX POWER: FAIL
3013 POSITION 4H OLD
3015 ANTENNA: TUNER
3016 SARPOSITION LOST
3079 PRINTER: ERROR
DISTRESS: RX
3122
DISTRESS: RELAY
URGENCY: RX
SAFETY: COM
SAFETY: POS
3123
SAFETY: TEST
ROUTINE: COM
ROUTINE: POLL
*1: ID number (MMSI) of the ship that sent the distress call is displayed.
*2: Nature of distress (Fire, Man overboard, etc.) is displayed.
*3: ID number (MMSI) of the ship that sent the distress relay call is displayed.
*4: ID number (MMSI) of the received calling station is displayed.
*5: "Individual call" or "Area call" is displayed.
*6: "Individual call" or Group ID number is displayed.
*7: 1 or 2
*8: From 1 to 99
6-10
Alert description
Priority
PA Hi-temp
Warning
No Transmission
RX works OK.
Position is too old.
Caution
Input new position.
ATU Hi-temp
Warning
No Transmission
RX works OK.
No position data.
Caution
Input data manually.
Check printer
Caution
condition.
DIST-ID:xxxxxxxxx
* 1
Warning
ccc...
* 2
DIST-ID:xxxxxxxxx
* 1
Warning
RLY-ID:yyyyyyyyy
* 3
RxID:xxxxxxxxx
* 4
Warning
* 5
Individual call
* 4
RxID:xxxxxxxxx
Caution
* 5
Individual call
* 4
RxID:xxxxxxxxx
Caution
Individual call
RxID:xxxxxxxxx
* 4
Caution
Individual call
* 4
RxID:xxxxxxxxx
Caution
* 6
Individual call
RxID:xxxxxxxxx
* 4
Caution
Individual call
* 6
Responsi
Occurrence conditions
Cate
Alert
bility
gory
instance
Recovery conditions
transfer
Detected high temperature of
the PA heat sink.
B
1
Returned to normal
temperature of the PA heat
sink.
Four hours passed without
position data input.
B
1
Input new position data.
Detected high temperature in
the antenna tuner.
B
1
Returned to normal
temperature in the antenna
tuner.
No position data input in 1
minute after startup, or the
position data is interrupted for
B
1
10 minutes.
Input new position data.
Detected serial printer error.
B
n
* 7
Recovered the serial printer
error.
Received distress call.
* 8
B
nn
Terminated the event of the
receiving distress call.
Received distress relay call.
B
nn
* 8
Terminated the event of the
receiving distress relay call.
Received urgency call.
B
nn
* 8
Terminated the event of the
receiving urgency call.
Received safety call (Individual
or Area).
B
* 8
nn
Terminated the event of the
receiving safety call.
Received safety call (Position
request).
B
nn
* 8
Terminated the event of the
receiving safety call.
Received safety call (Test).
B
nn
* 8
Terminated the event of the
receiving safety call.
Received routine call
(Individual or Group).
B
* 8
nn
Terminated the event of the
receiving routine call.
Received polling call
(Individual or Group).
B
nn
* 8
Terminated the event of the
receiving polling call.