Installation, cont'd

Audio output

The 5-pole captive screw audio output connector is used for
both balanced and unbalanced audio. When the connector is
wired for unbalanced audio, the gain is unity.
Tip
NO GROUND HERE
Sleeves
Tip
NO GROUND HERE
Unbalanced Output
C
For unbalanced audio, connect both sleeves
to the center contact ground. DO NOT connect
the sleeves to the negative (-) contacts.
Do not tin the wires!
Wiring the audio output connector

Wiring the Remote/Autoswitching Connector

The 5-pin, 3.5 mm Remote/Auto-Sw captive screw connector
is used for optional RS-232 communication and/or to enable
autoswitching between inputs connected to the SW2/SW4.

Wiring for RS-232

To connect your computer or control system to the RS-232
connector, use a male 9-pin, D-to-bare-wire RS-232 cable or a
universal control cable (UC 50', UC 100', or UC 200'). One end of
the UC cable is terminated with a female 9-pin D connector, and
the other end is unterminated. Wire the unterminated end to
the provided five-pin captive screw plug.
The following diagram shows the UC cable's pin assignments.
Color
Black
9
Gray
8
Purple
7
Blue
6
Green ( )
5
Yellow
4
Orange (Rx)
3
Red (Tx)
2
Brown
1
Pin #
SW DVI A Series
Switcher
UC cable pin assignment color codes
2-12
SW DVI A Series • Installation
Tip
Ring
Sleeves
Tip
Ring
Balanced Output
1
5
UC Cable
Shield
Connector Shell
Computer
or Control
System
6
9
1.
Wire the RS-232 cable to the five-pole captive screw plug,
provided with the SW2/SW4, as described below. Connect
only the red, orange, and green wires in the cable; and use
only the first three pins on the connector, starting at the
left.
a. Connect the red wire to the first pin on the left, which
plugs into the Tx (transmit) port.
b. Connect the orange wire to the second pin, which plugs
into the Rx (receive) port.
c. Connect the green wire to the third pin, which plugs
into the ground port, marked with this symbol:
2.
Plug the five-pole connector into the Remote/Auto-SW
receptacle on the switcher's rear panel.
The following figure shows how to wire this shared connector
for RS-232.
Remote/Auto-Sw
SW 2 or SW 4 DVI A Switcher
Tx Rx
A S
Rear Ranel
RS-232 Port
Green
Ground
Orange
Rx
Receive
Red
Tx
Transmit
If you use cable that has a
drain wire, tie the drain wire to
ground at both ends.
RS-232/autoswitch connector pin assignments

Enabling autoswitching

You can set up the SW2/SW4 to automatically select the active,
connected input. If two or more inputs are active, the input with
the highest number is selected. When autoswitching is in effect,
the green Auto Switch LED on the front panel lights, and the
front panel input selection buttons are disabled.
SW DVI A Series • Installation
_
Connect a ground wire between
the switcher and the computer or
control system.
Transmit (Tx)
3
Receive (Rx)
2
9 pin HD
Connector
To Computer or
Control System
RS-232 Port
2-13