Turning Off The Appliance; Complete Shutdown - Honeywell VR9105V Installation Instructions Manual

Direct ignition gas control with integrated 1:1 regulator
Hide thumbs Also See for VR9105V:
Table of Contents

Advertisement

Available languages

Available languages

VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR
INSTRUCTIONS TO THE
HOMEOWNER
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:
1. Before lighting, smell around the appliance for
gas. Be sure to smell next to the floor because
LP gas is heavier than air. If you smell gas:
a. Turn off the gas supply at the appliance
service valve. On LP gas systems, turn off
the gas supply at the gas tank.
b. Do not light any appliances in the house.
c. Do not touch electrical switches or use the
phone.
d. Leave the building and use a neighbor's
phone to call your gas supplier.
e. If you cannot reach your gas supplier, call
the fire department.
2. Replace the gas control in the event of any
physical damage, tampering, bent terminals,
missing or broken parts, stripped threads, or
evidence of exposure to heat.
IMPORTANT
Follow the operating instructions provided by
the heating appliance manufacturer. The
information below describes a typical control
application, but the specific controls used and
the procedures outlined in your appliance
manufacturer instructions can differ, requiring
special instructions.
Automation and Control Solutions
Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario M1V 4Z9
customer.honeywell.com
To Turn ON Appliance
STOP! Read the Warnings
Above Before Proceeding.
1. The lighting sequence on this appliance is
automatic; do not attempt to manually light the
main burner.
2. If the appliance does not come on when the
thermostat is set several degrees above room
temperature, set the thermostat to its lowest setting
to reset the safety control.
3. Remove the burner access panel if provided on
your appliance.
4. Connect the plug to the coil connector.
5. Wait five minutes to allow any gas in the
combustion chamber to vent. Then if you smell
gas, STOP! Follow Step 1 in the Warning above. If
you do not smell gas, continue with the next step.
6. If you do not smell gas, connect the plug to the coil
connector.
7. Replace the burner access panel.
8. Reset the thermostat to the desired temperature.
9. If the appliance does not turn on, pull out the plug
and contact a qualified service technician for
assistance.

Turning Off the Appliance

Vacation Shutdown
Set the thermostat to the desired room temperature while
you are away.

Complete Shutdown

1. Turn off power to the appliance.
2. Turn off the gas supply to the appliance.
3. Pull out the plug from coil connector. Appliance will
completely shut off.
4. Follow the procedure in the Instructions to the
Homeowner section above to resume normal
operation.
® U.S. Registered Trademark
© 2010 Honeywell International Inc.
69-2471EF—01
M.S. 12-10
Printed in U.S.A.

Advertisement