Honeywell VR9105V Installation Instructions Manual
Honeywell VR9105V Installation Instructions Manual

Honeywell VR9105V Installation Instructions Manual

Direct ignition gas control with integrated 1:1 regulator
Hide thumbs Also See for VR9105V:

Advertisement

Available languages

Available languages

Quick Links

VR9105V, F and VR9205V, F
Direct Ignition Gas Control with
Integrated 1:1 Regulator
APPLICATION
The VR9105V, F and VR9205V, F series gas controls with
1:1 gas/air regulator have been developed for application
in domestic appliances with premix burners and automatic
ignition. They have been optimized for direct ignition
applications. VR9105V and VR9205V series gas controls
with 1:1 gas/air regulator can be used alone in direct
burner ignition application. A plug with an integrated
rectifier circuit then has to be used on the gas control
when working with AC voltage.
Inlet x Outlet
Model
Size (in.)
VR9105V, F
1/2 x END
VR9105V, F
1/2 x SIDE
VR9205V, F
1/2 x END
VR9205V, F
1/2 x SIDE
a
Capacity based on 1000 Btu/ft
at 0.25 kPa pressure drop).
b
Minimum and Maximum regulation is at the max fire. Minimum regulation at low fire is 18 KBtu/h at 0.7 in. WC outlet
pressure.
Model Number
Ambient Temperature
Suffix Letter
V
F
a
For detailed information about Venturi Manifold see Installation Instruction sheet 69-2484EF.
SPECIFICATIONS
Body Pattern: See Fig. 1 and Fig. 2.
Electrical Ratings:
Voltage and Frequency: 24 Vrac, 50/60 Hz.
Current Draw: 0.42 A.
Table 1. Valve Capacity.
CSA Certified
Capacity
KBtu/h
140
3
, 0.64 sp gr natural gas at 1 in. wc pressure drop (37.3 MJ/m
Table 2. Model Number Suffix Letter Designation.
Range
Standard opening with integrated 1:1 regulator
32 °F to 158 °F
(0 °C to 70 °C)
Standard opening with integrated 1:1 regulator and Venturi manifold
INSTALLATION INSTRUCTIONS
VR9105F and VR9205F series gas controls with 1:1 gas/
air regulator and integrated venturi manifold are gas/air
mixing units that allows modulation of a premix burner with
constant gas/air ratio. The modulation is accomplished by
changing the fan speed. The venturi generates a negative
pressure against ambient pressure by which the gas is
drawn through the gas valve outlet. Detailed information
about the Venturi Manifold can be found in the installation
instructions 69-2484EF.
• Valve capacities are shown in Table 1.
• For suffix letter designation, see Table 2.
a
CSA Certified Minimum
Regulation
KBtu/h
b
40
Pressure Regulator Type
Capacity: See Table 1.
Regulation Range: See Table 1.
Natural-LP Gas Conversion Kits: Valve is not
convertible.
Approvals:
CSA Design Certificate. File # 158158
CSA Certified Maximum
Regulation
KBtu/h
200
3
, 0.64 sp gr natural gas
69-2471EF-01
a

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell VR9105V

  • Page 1 Integrated 1:1 Regulator INSTALLATION INSTRUCTIONS APPLICATION The VR9105V, F and VR9205V, F series gas controls with VR9105F and VR9205F series gas controls with 1:1 gas/ 1:1 gas/air regulator have been developed for application air regulator and integrated venturi manifold are gas/air...
  • Page 2: Planning The Installation

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR INLET 1/2-14 1:1 REGULATOR REFERENCE PRESSURE CONNECTION OUTLET OUTLET 1/2-14 PRESSURE TAP 1/6-27 3-7/16 3-3/16 (87) (80) 7/8 (22) 1-3/16 (30) 1-3/16 INLET PRESSURE 1-1/16 5 (127)
  • Page 3: Corrosive Chemicals

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR Frequent Cycling WARNING This control is designed for use on appliances that typically cycle three to four times an hour only during the Fire or Explosion Hazard.
  • Page 4 VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR Converting Gas Control from 3. Install a sediment trap in the supply line to the control. See Fig. 4. Natural Gas to LP Gas (or LP Gas...
  • Page 5: Electrical Connection

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR TWO IMPERFECT THREADS GAS CONTROL PIPE THREAD PIPE THE AMOUNT APPLY A MODERATE AMOUNT OF SHOWN IN TABLE FOR PIPE COMPOUND TO PIPE ONLY INSERTION INTO GAS CONTROL (LEAVE TWO END THREADS BARE).
  • Page 6: Startup And Checkout

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR STARTUP AND CHECKOUT IMPORTANT 1. Do not exceed input rating stamped on appli- ance nameplate or manufacturer's recom- mended burner orifice size(s). Make certain Perform Gas Leak Test primary air supply to main burner is properly adjusted for complete combustion.
  • Page 7: Maintenance

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR SERVICE IMPORTANT Adjustments must be made in the final gas valve mounting position to avoid shift caused by the orientation. WARNING • Turn offset adjustment screw counter clockwise to increase or clockwise to decrease outlet pres- Fire or Explosion Hazard.
  • Page 8: Turning Off The Appliance

    VR9105V, F AND VR9205V, F DIRECT IGNITION GAS CONTROL WITH INTEGRATED 1:1 REGULATOR INSTRUCTIONS TO THE To Turn ON Appliance HOMEOWNER STOP! Read the Warnings Above Before Proceeding. WARNING 1. The lighting sequence on this appliance is automatic; do not attempt to manually light the Fire or Explosion Hazard.
  • Page 9: Caractéristiques

    1:1 et collecteur Venturi intégré sont des unités de mélange gaz/air qui permettent la modulation Les régulateurs à gaz série VR9105V, F et VR9205V, F d'un brûleur de prémélange avec taux gaz/air constant. avec régulateurs gaz/air 1:1 ont été développés pour les La modulation s'accomplit en modifiant la vitesse du applications dans les appareils domestiques avec brûleurs...
  • Page 10: Préparation De L'installation

    RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ ENTRÉE 1/2-14 RÉGULATEUR 1:1 RACCORD DE PRESSION DE RÉFÉRENCE PRISE DE SORTIE PRESSION 1/2-14 DE SORTIE 1/6-27 3-7/16 3-3/16 (87) (80) 7/8 (22) 1-3/16 (30)
  • Page 11 RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ INSTALLATION Mises en marche et arrêts fréquents Lors de l'installation de ce Ce régulateur est conçu pour une utilisation sur les appareils dont les cycles n'ont lieu que trois ou quatre fois produit…...
  • Page 12 RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ Pour garantir un bon fonctionnement, suivre ces MISE EN GARDE instructions : • Placer le régulateur à gaz dans une zone bien ventilée. Risque de dommages matériels.
  • Page 13 RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ Raccords de pression d'air DEUX FILETAGES La différence de pression d'air doit être connectée au RÉGULATEUR À GAZ IMPARFAITS raccord de pression d'air. Voir les Fig. 1 et 2.
  • Page 14 RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ Tout le câblage doit être conforme aux codes et aux 3. Allumer le brûleur principal. S'éloigner du brûleur réglementations électriques locales. principal lors de l'allumage pour éviter les blessures 1.
  • Page 15: Entretien

    RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ 6. Régler le thermostat à une température inférieure à MISE EN GARDE la température ambiante et attendre une minute. 7. Activer le système sur un cycle complet pour...
  • Page 16 RÉGULATEUR À GAZ À ALLUMAGE DIRECT VR9105V, F ET VR9205V, F AVEC RÉGULATEUR 1:1 INTÉGRÉ 5. Si la tension adéquate est présente, replacer le IMPORTANT régulateur. Suivre les instructions de fonctionnement fournies par le fabricant de l'appareil de chauffage. Les informations ci-dessous décrivent une application...

This manual is also suitable for:

Vr9105fVr9205vVr9205f

Table of Contents