Command/response table for SIS commands (continued)
Command
Audio input gain and attenuation
N The set gain (G) and set attenuation (g) commands are case sensitive. The increment, decrement, and read commands are not case sensitive.
Set input audio gain to
+dB value
Example:
Set input audio
attenuation to -dB value
Increment gain
Example:
Decrement gain
Example:
Read input gain
X!
= Input number
N
X(
= Audio gain
X1)
= Numeric dB value
X1!
= Audio attenuation
Command/response table for SIS commands (continued)
Command
Local audio output volume
Set the local audio
volume to a specific
value
Example:
Increment volume
Example:
Decrement volume
Read output volume
Audio or RS-232 mute commands
Audio or RS-232 mute
Audio or RS-232
unmute
Read audio or RS-232
mute
X1@
= Volume adjustment range
N
X1#
= Mute
ASCII Command
Response
(host to unit)
(unit to host)
X!
X(
X!
*
G
In
•Aud
1*2G
In01•Aud+02
X!
X1!
X!
*
g
In
•Aud
X!
X!
+G
In
•Aud
5+G
In05•Aud+03
X!
X!
-G
In
•Aud
7-G
In07•Aud-09
X!
X1)]
G
1 – 6
0 – 24 (1 dB/step)
–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)
1 – 18 (1 dB/step)
ASCII Command
Response
(host to unit)
(unit to host)
X1@
X1@]
V
Vol
50v
Vol50
X1@]
+V
Vol
+V
Vol51
X1@]
-V
Vol
X1@]
V
1Z
Amt1
0Z
Amt0
X1#]
Z
0 – 100
0 = off
1 = on (muted)
Additional description
X1)]
]
Set input 1 audio gain to +2 dB.
X1)]
X1)]
Increase gain by 1 dB.
]
Increase audio input 5 level from +2 dB to +3 dB.
X1)]
Decrease gain by 1 dB.
]
Decrease audio input 7 level from -8 dB to -9 dB.
Additional description
]
Set output 1 volume to 50%.
Increment volume by 1%.
]
Decrease volume by 1%.
]
Mute output audio or RS-232 (audio off).
]
Unmute output audio or RS-232 (audio on).
1 = mute on, 0 = mute off.
Need help?