6.16 PTZ SETTING MENU

PTZ SETTING MENU
PTZ ENABLE: OFF
PTZ Port: RS485
PROTOCOL: PELCO-D
BAUD RATE: 9600
PTZ ADDRESS:
CH1: 001
CH2: 002
CH3: 003
CH4: 004
CH5: 005
CH6: 006
CH7: 007
CH8: 008
The EDSR600/900/1600 Recorder from FW 1.09 provides telemetry control over network.
Local device telemetry control at the EDSR recorder is not possible. Telemetry bus may be
connected to RS-232 or RS-485.
In the PTZ SETTING MENU, we define
PTZ ENABLE: ON activates telemetry function / OFF disable telemetry function.
PTZ - Port:
Selection of active telemetry port, RS232 or RS485.
ATTENTION:
telemetry must be connected to the RS232 - port (with interface converter)
PROTOCOL:
Supported protocols: PELCO-D, PELCO-P, EVERFOCUS* und VPROTECT*
(* reserved for future us, currently not supported)
BAUD RATE: There are 6 telemetry transmission rates, selectable 1200, 2400, 4800, 9600,
19200, 38400 baud rate.
PTZ-ADRESS: Telemetry receiver / Dome camera address assignment to the video inputs
Turn the JOG dial clockwise or counter-clockwise to select the options.
Press ENTER key to confirm the option and move to next column.
ENTER
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU
CH9: 009
CH10: 010
CH11: 011
CH12: 012
CH13: 013
CH14: 014
CH15: 015
CH16: 016
If the EDSR is remote controlled by RS-485 keyboard, and