INTRODUCTION ON INSTALLATION
INTRODUCTION ON INSTALLATION
Remember that:
Remember that:
• •
the product must be installed by qualified staff
the product must be installed by qualified staff
who can issue a Declaration of Conformity
who can issue a Declaration of Conformity
• •
all the local and national laws and the European
all the local and national laws and the European
Standards must be met for installation and use of
Standards must be met for installation and use of
the product.
the product.
• •
In the event of installation in apartment blocks, ask
In the event of installation in apartment blocks, ask
the administrator's opinion beforehand.
the administrator's opinion beforehand.
We give some general instructions below, however
We give some general instructions below, however
these do not obviate the need to comply with local
these do not obviate the need to comply with local
regulations and do not affect the installer's liability for
regulations and do not affect the installer's liability for
the installation.
the installation.
The
The
hot
hot
(natural convection) or with the aid of a
(natural convection) or with the aid of a
ventilation system (AIR DIFFUSER KIT)
ventilation system (AIR DIFFUSER KIT)
to be purchased separately and applied
to be purchased separately and applied
BEFORE
BEFORE
process.
process.
Contact your retailer for any further
Contact your retailer for any further
information.
information.
Checking the suitability of the installation
premises
The volume of the room must be over 40 m
Installation is not permitted in bedrooms,
bathrooms or premises with other products that
10
take in air for combustion of the same premises
or in premises with an explosive atmosphere. Any
extractor fans, if working in the same environment
or space in which the product is installed, can
cause draft problems.
In Italy, check compatibility pursuant to UNI 10683
and UNI 7129 in the presence of gas products.
The floor must be able to support the weight of the
product and the accessories.
Protection from heat and safe distances
All the surfaces of the building adjacent to the pro-
duct must be protected against heating.The insulation
measurements to implement depend on the type of
surface present.
The product must be installed in accordance with the
following safety instructions:
- minimum distance of 20 cm from flammable materials
along the sides and back.
- no flammable materials may be kept within 80 cm
from the front of the appliance.
INSTALLATION
air
air
can
can
circulate
circulate
naturally
naturally
completing
completing
the
the
installation
installation
3
CHIMNEY SYSTEM
CHIMNEY SYSTEM
(Smoke channel, chimney flue and chimney
(Smoke channel, chimney flue and chimney
stack)
stack)
This chapter is drafted according to the European
Standards EN 13384, EN 1443, EN 1856, EN 1457. The
installation technicians must take into consideration
these and any other local standards. The manual
should in no way be considered a replacement for the
laws in force.
The product must be connected to a suitable smoke
discharge that guarantees completely safe evacuation
of the smoke produced by combustion.
Before positioning the product, you need to check the
chimney flue is suitable.
SMOKE CHANNEL, CHIMNEY FLUE
SMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fireplace with the chimney flue inlet) and the
chimney flue must, along with other legal provisions:
receive the discharge for a single product (multiple
product discharges are not permitted together)
have a mainly vertical development
no section should have a reserve slope
have an inner section preferably circular and
however with a ratio between sides lower than 1.5
complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
be created with materials with a fire reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
be appropriately certified, with an appropriate
fireplace plate, if metal
keep the initial section
Electricity lines
There must be no electricity lines in the
walls or ceiling of the fireplace installation
area.