Positioning, Installation And Maintenance; Positioning; Installation; Electrical Connections And Equipotential Bonding - Tecnoinox B8FXGN9 Instruction Manual For Installation, Maintenance And Use

Freestanding 80lt gas tilting bratt pan with stainless steel tank on closed cabinet
Table of Contents

Advertisement

POSITIONING, INSTALLATION AND MAINTENANCE

2
2.1

POSITIONING

− Remove all the packaging and check that the appliance is in perfect conditions. In case of visible damage,
do not connect the appliance and notify the sales point immediately.
− Remove the PVC protection from the panels.
− Dispose of packaging according to regulations. Generally material is divided according to composition and
should be delivered to the waste disposal service.
− Maintain a distance of 3 cm between the back (chimney) of the appliance and the wall. There are no
particular prescriptions regarding side distances from other appliances or walls, however it is advisable to
leave enough space in case of maintenance and/or repairs. It is advisable to fit a suitable heat insulation if
the appliance is in direct contact with inflammable walls.
− The appliance must stand level. Small differences in level can be eliminated by screwing or unscrewing
the adjustable feet: A significantly uneven or sloping stance can affect the operation of the appliance
adversely.
− The device can be put in place or as a single unit or in series with other equipment.
2.2

INSTALLATION

Only qualified technicians must perform the installation, maintenance and test of the
appliance.
Before connecting any parts of the appliance to supplies, make sure that the latter is
equivalent the requirements stated in the technical data plate, if the appliance has
been designed for these supplies.
2.2.1

ELECTRICAL CONNECTIONS AND EQUIPOTENTIAL BONDING

Warning! :
The appliance is supplied to operate according to the power supply indicated on the
data plate.
− As mentioned, the appliance must be connected to the power supply by way of a multiple pole main
isolating switch and protection device that must be proportioned to the power of the appliance (1 mA per
kW of rated power).
− The earthing system must be efficient.
− As this appliance is type X equipment (delivery with power cable and without plug), the other hardware
needed to make the connection to the electrical power supply must be provided by the installer.
− The power cable shall be of the kind described in the paragraph "Technical data" and shall be resistant to
oil (type H05RN-F o H07RN-F).
− The appliance must incorporate an equipotential system.
INSTRUCTION MANUAL FOR INSTALLATION, MAINTENANCE AND USE Rev-01
RECTANGULAR BRATT PANS GAS TYPE "BR8G080I - BR8G080I.M" "BR9G090I –
11
GB
BR9G090I.M" "BR1G120I – BR1G120I.M" "BR1G150I – BR1G150I.M" "BR1G160I –
BR1G160I.M" "BR1G200I – BR1G200I.M"

Advertisement

Table of Contents
loading

Table of Contents